TY - JOUR
T1 - Use of adenosine echocardiography for diagnosis of coronary artery disease
AU - Zoghbi, William A.
PY - 1991/1/1
Y1 - 1991/1/1
N2 - Two-dimensional echocardiography combined with exercise is sensitive and specific in the detection of coronary artery disease (CAD) by demonstrating transient abnormallties in wall motion. Frequently, however, patients cannot achieve maximal exercise because of various factors. Pharmacologic stress testing with intravenous adenosine was evaluated as a means of detecting CAD in a noninvasive manner. Patients with suspected CAD underwent echocardiographic imaging and simultaneous thallium 201 single-photon emission computed tomography during the intravenous administration of 140 μg/kg/min of adenosine. An increase in heart rate, decrease in blood pressure, and increase in double product were observed during adenosine administration. Initial observations revealed that wall motion abnormalities were induced by adenosine in areas of perfusion defects. The adenosine infusion was well tolerated, and symptoms disappeared within 1 to 2 minutes after termination of the infusion. Therefore preliminary observations suggest that adenosine echocardiography appears to be useful in the assessment of CAD.
AB - Two-dimensional echocardiography combined with exercise is sensitive and specific in the detection of coronary artery disease (CAD) by demonstrating transient abnormallties in wall motion. Frequently, however, patients cannot achieve maximal exercise because of various factors. Pharmacologic stress testing with intravenous adenosine was evaluated as a means of detecting CAD in a noninvasive manner. Patients with suspected CAD underwent echocardiographic imaging and simultaneous thallium 201 single-photon emission computed tomography during the intravenous administration of 140 μg/kg/min of adenosine. An increase in heart rate, decrease in blood pressure, and increase in double product were observed during adenosine administration. Initial observations revealed that wall motion abnormalities were induced by adenosine in areas of perfusion defects. The adenosine infusion was well tolerated, and symptoms disappeared within 1 to 2 minutes after termination of the infusion. Therefore preliminary observations suggest that adenosine echocardiography appears to be useful in the assessment of CAD.
UR - http://www.scopus.com/inward/record.url?scp=0025802915&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025802915&partnerID=8YFLogxK
U2 - 10.1016/0002-8703(91)90802-O
DO - 10.1016/0002-8703(91)90802-O
M3 - Article
C2 - 2063759
AN - SCOPUS:0025802915
SN - 0002-8703
VL - 122
SP - 285
EP - 292
JO - American Heart Journal
JF - American Heart Journal
IS - 1 PART 1
ER -