N2 - OBJECTIVE. To compare the efficacy of universal gloving with emollient-impregnated gloves with standard contact precautions for the control of multidrug-resistant organisms (MDROs) and to measure the effect on healthcare workers' (HCWs') hand skin health. DESIGN. Prospective before-after trial. SETTING. An 18-bed surgical intensive care unit. METHODS. During phase 1 (September 2007 through March 2008) standard contact precautions were used. During phase 2 (March 2008 through September 2008) universal gloving with emollient-impregnated gloves was used, and no contact precautions. Patients were screened for vancomycin-resistant Enterococcus (VRE) and methicillin-resistant Staphylococcus aureus (MRSA). HCW hand hygiene compliance and hand skin health and microbial contamination were assessed. The incidences of device-associated infection and Clostridium difficile infection (CDI) were determined. RESULTS. The rate of compliance with contact precautions (phase 1) was 67%, and the rate of compliance with universal gloving (phase 2) was 78% (P = 0.1 ). Hand hygiene compliance was higher during phase 2 than during phase 1 (before patient care, 40% vs 35% of encounters; P = .001; after patient care, 63% vs 51% of encounters; P < .001). No difference was observed in MDRO acquisition. During phases 1 and 2, incidences of device-related infections, in number of infections per 1,000 device-days, were, respectively, 3.7 and 2.6 for bloodstream infection (P = .10), 8.9 and 7.8 for urinary tract infection (P = .10), and 1.0 and 1.1 for ventilator-associated pneumonia (P = .09). The CDI incidence in phase 1 and in phase 2 was, respectively, 2.0 and 1.4 cases per 1,000 patient-days (P = .53). During phase 1, 29% of HCW hand cultures were MRSA positive, compared with 13% during phase 2 (P = .17); during phase 1, 2% of hand cultures were VRE positive, compared with 0 during phase 2 (Pp.16). Hand skin health improved during phase 2. CONCLUSIONS. Compared with contact precautions, universal gloving with emollient-impregnated gloves was associated with improved hand hygiene compliance and skin health. No statistically significant change in the rates of device-associated infection, CDI, or patient MDRO acquisition was observed. Universal gloving may be an alternative to contact precautions.
AB - OBJECTIVE. To compare the efficacy of universal gloving with emollient-impregnated gloves with standard contact precautions for the control of multidrug-resistant organisms (MDROs) and to measure the effect on healthcare workers' (HCWs') hand skin health. DESIGN. Prospective before-after trial. SETTING. An 18-bed surgical intensive care unit. METHODS. During phase 1 (September 2007 through March 2008) standard contact precautions were used. During phase 2 (March 2008 through September 2008) universal gloving with emollient-impregnated gloves was used, and no contact precautions. Patients were screened for vancomycin-resistant Enterococcus (VRE) and methicillin-resistant Staphylococcus aureus (MRSA). HCW hand hygiene compliance and hand skin health and microbial contamination were assessed. The incidences of device-associated infection and Clostridium difficile infection (CDI) were determined. RESULTS. The rate of compliance with contact precautions (phase 1) was 67%, and the rate of compliance with universal gloving (phase 2) was 78% (P = 0.1 ). Hand hygiene compliance was higher during phase 2 than during phase 1 (before patient care, 40% vs 35% of encounters; P = .001; after patient care, 63% vs 51% of encounters; P < .001). No difference was observed in MDRO acquisition. During phases 1 and 2, incidences of device-related infections, in number of infections per 1,000 device-days, were, respectively, 3.7 and 2.6 for bloodstream infection (P = .10), 8.9 and 7.8 for urinary tract infection (P = .10), and 1.0 and 1.1 for ventilator-associated pneumonia (P = .09). The CDI incidence in phase 1 and in phase 2 was, respectively, 2.0 and 1.4 cases per 1,000 patient-days (P = .53). During phase 1, 29% of HCW hand cultures were MRSA positive, compared with 13% during phase 2 (P = .17); during phase 1, 2% of hand cultures were VRE positive, compared with 0 during phase 2 (Pp.16). Hand skin health improved during phase 2. CONCLUSIONS. Compared with contact precautions, universal gloving with emollient-impregnated gloves was associated with improved hand hygiene compliance and skin health. No statistically significant change in the rates of device-associated infection, CDI, or patient MDRO acquisition was observed. Universal gloving may be an alternative to contact precautions.
UR - http://www.scopus.com/inward/record.url?scp=77951056796&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77951056796&partnerID=8YFLogxK
U2 - 10.1086/651671
DO - 10.1086/651671
M3 - Article
C2 - 20350197
AN - SCOPUS:77951056796
SN - 0899-823X
VL - 31
SP - 491
EP - 497
JO - Infection Control and Hospital Epidemiology
JF - Infection Control and Hospital Epidemiology
IS - 5
ER -