TY - JOUR
T1 - Tolerance and diagnostic accuracy of an abbreviated adenosine infusion for myocardial scintigraphy
T2 - A randomized, prospective study
AU - Treuth, Mark G.
AU - Reyes, Guillermo A.
AU - He, Zuo Xiang
AU - Cwajg, Eduardo
AU - Mahmarian, John J.
AU - Verani, Mario S.
PY - 2001
Y1 - 2001
N2 - Background. The objectives of this study were 2-fold: (1) to determine the tolerance of adenosine perfusion tomography with the use of an abbreviated (3-minute) infusion in comparison to the standard (6-minute) infusion, and (2) to assess the relative diagnostic accuracy of a 3-minute adenosine infusion in patients referred for arteriography. An abbreviated adenosine infusion may decrease the frequency and duration of side effects and be a more cost-effective alternative. Methods and Results. We prospectively randomized 599 patients undergoing adenosine myocardial perfusion tomography to either a 3-minute or 6-minute adenosine infusion at 140 μg/kg per minute. Among the 599 enrolled patients, 142 subsequently underwent coronary angiography. Patients randomized to the 3-minute adenosine infusion tolerated the procedure better than those randomized to the standard infusion (P < .01). Flushing, headache, neck pain, and atrioventricular block were all significantly less frequent (P < .01) with the abbreviated infusion. Moreover, patients receiving the abbreviated infusion had less hypotension and tachycardia (P < .05). The sensitivity of the test for detection of coronary artery disease was 88% for both the 3- and 6-minute infusions. In patients with abnormal scan results, perfusion defect size was slightly larger in those receiving a 6-minute infusion versus those receiving a 3-minute infusion (P = .05). Conclusions. An abbreviated 3-minute adenosine infusion, in combination with perfusion tomography, has similar sensitivity for detection of coronary artery disease and is better tolerated than the standard 6-minute infusion.
AB - Background. The objectives of this study were 2-fold: (1) to determine the tolerance of adenosine perfusion tomography with the use of an abbreviated (3-minute) infusion in comparison to the standard (6-minute) infusion, and (2) to assess the relative diagnostic accuracy of a 3-minute adenosine infusion in patients referred for arteriography. An abbreviated adenosine infusion may decrease the frequency and duration of side effects and be a more cost-effective alternative. Methods and Results. We prospectively randomized 599 patients undergoing adenosine myocardial perfusion tomography to either a 3-minute or 6-minute adenosine infusion at 140 μg/kg per minute. Among the 599 enrolled patients, 142 subsequently underwent coronary angiography. Patients randomized to the 3-minute adenosine infusion tolerated the procedure better than those randomized to the standard infusion (P < .01). Flushing, headache, neck pain, and atrioventricular block were all significantly less frequent (P < .01) with the abbreviated infusion. Moreover, patients receiving the abbreviated infusion had less hypotension and tachycardia (P < .05). The sensitivity of the test for detection of coronary artery disease was 88% for both the 3- and 6-minute infusions. In patients with abnormal scan results, perfusion defect size was slightly larger in those receiving a 6-minute infusion versus those receiving a 3-minute infusion (P = .05). Conclusions. An abbreviated 3-minute adenosine infusion, in combination with perfusion tomography, has similar sensitivity for detection of coronary artery disease and is better tolerated than the standard 6-minute infusion.
KW - Coronary artery disease
KW - Myocardial scintigraphy
KW - Short adenosine infusion
UR - http://www.scopus.com/inward/record.url?scp=0034769276&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034769276&partnerID=8YFLogxK
U2 - 10.1067/mnc.2001.116167
DO - 10.1067/mnc.2001.116167
M3 - Article
C2 - 11593218
AN - SCOPUS:0034769276
SN - 1071-3581
VL - 8
SP - 548
EP - 554
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
IS - 5
ER -