TY - JOUR
T1 - Time-resolved three-dimensional contrast-enhanced magnetic resonance angiography in patients with chronic expanding and stable aortic dissections
AU - Trojan, Michael
AU - Rengier, Fabian
AU - Kotelis, Drosos
AU - Müller-Eschner, Matthias
AU - Partovi, Sasan
AU - Fink, Christian
AU - Karmonik, Christof
AU - Böckler, Dittmar
AU - Kauczor, Hans Ulrich
AU - Von Tengg-Kobligk, Hendrik
N1 - Publisher Copyright:
© 2017 Michael Trojan et al.
PY - 2017
Y1 - 2017
N2 - Objective. To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA) is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. Materials and Methods. 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years). 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level) resulting in respective time-intensity curves. Results. For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group (p=0.027 and p=0.003), and upward and downward slopes of time-intensity curves were significantly steeper (p=0.015 and p=0.005). The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group (p=0.01). Conclusions. 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections.
AB - Objective. To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA) is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. Materials and Methods. 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years). 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level) resulting in respective time-intensity curves. Results. For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group (p=0.027 and p=0.003), and upward and downward slopes of time-intensity curves were significantly steeper (p=0.015 and p=0.005). The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group (p=0.01). Conclusions. 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections.
UR - http://www.scopus.com/inward/record.url?scp=85042226633&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042226633&partnerID=8YFLogxK
U2 - 10.1155/2017/5428914
DO - 10.1155/2017/5428914
M3 - Article
C2 - 29317855
AN - SCOPUS:85042226633
SN - 1555-4309
VL - 2017
JO - Contrast Media and Molecular Imaging
JF - Contrast Media and Molecular Imaging
M1 - 5428914
ER -