Skip to main navigation Skip to search Skip to main content

The perfect match: Aortic valve sizing to maximize hemodynamic performance and survival

Barbara C.S. Hamilton, Shinichi Fukuhara, Michael Boulware, Robert B. Hawkins, Sachin S. Goel, Bo Yang, Himanshu J. Patel, Gorav Ailawadi, Stanley J. Chetcuti, Shuzhen Li, Mikhale Grundtner, Julie A. Linick, Michael J. Reardon, G. Michael Deeb

Research output: Contribution to journal › Article › peer-review

Abstract

Objective: We assessed the value of using a size ratio of implanted valve opening diameter to native annular diameter to determine postoperative hemodynamics and survival after surgical aortic valve replacement. Methods: In total, 1519 patients from 3 trials had a preoperative computed tomography scan. A size ratio was created using the implanted valve's Ebels' prosthetic valve−derived effective diameter (ED) and the patient's computed tomography perimeter−derived native annular diameter (CTD). Restricted cubic spline curves showed the association between size ratio and hemodynamic performance. Patients were divided into 3 ratio groups: <80%, 80% to 90%, and >90%. Hemodynamic performance was evaluated yearly for 5 years. Multivariable proportional hazard regression examined the association between size ratio and 5-year survival. Results: Mean valve gradient, peak velocity, effective orifice area (EOA), indexed EOA, dimensionless velocity index, and prosthesis-patient mismatch were significantly better advancing from the 80% to the 90% groups (P < .001). The >90% group had a single-digit mean valve gradient, peak velocity ≤2.0 m/s, EOA ≥2.0 cm2, indexed EOA ≥1.0 cm2/m2, dimensionless velocity index ≥0.5, and no prosthesis-patient mismatch ≥85% at 1 and 5 years. Size ratio was an independent predictor of mortality with survival benefit through 5 years (80%-90% vs <80%, hazard ratio, 0.752; 95% confidence interval, 0.611-0.927, P = .008; >90% vs <80%, hazard ratio, 0.712; 95% confidence interval, 0.506-1.001, P = .05). Conclusions: An ED/CTD size ratio >90% is associated with optimal postoperative hemodynamic performance and improved 5-year survival. Preoperative ED/CTD ratio provides the ideal implanted valve size and helps determine if annular enlargement is necessary.

Original languageEnglish (US)
Article number100088
JournalJTCVS Structural and Endovascular
Volume8
DOIs
StatePublished - Dec 2025

Keywords

  • CT scan perimeter-derived aortic annular diameter (CTD)
  • Ebels' effective diameter (ED)
  • annular enlargement
  • aortic valve sizing
  • size ratio match
  • surgical aortic valve replacement

ASJC Scopus subject areas

  • Surgery
  • Cardiology and Cardiovascular Medicine
  • Pulmonary and Respiratory Medicine

Fingerprint

Dive into the research topics of 'The perfect match: Aortic valve sizing to maximize hemodynamic performance and survival'. Together they form a unique fingerprint.

Cite this