TY - JOUR
T1 - Stent thrombosis with second-generation drug-eluting stents compared with bare-metal stents network meta-analysis of primary percutaneous coronary intervention trials in st-segment-elevation myocardial infarction
AU - Philip, Femi
AU - Agarwal, Shikhar
AU - Bunte, Matthew C.
AU - Goel, Sachin S.
AU - Tuzcu, E. Murat
AU - Ellis, Stephen
AU - Kapadia, Samir R.
PY - 2014/2
Y1 - 2014/2
N2 - Background-The relative safety of drug-eluting stents (DESs) and bare-metal stents (BMSs) with respect to stent thrombosis (ST) continues to be debated. There are limited data comparing safety and efficacy of second-generation DES to BMS. We compared the clinical outcomes between second-generation DES and BMS for primary percutaneous coronary intervention using network meta-analysis. Methods and Results-Randomized controlled trials comparing stent types (first-generation DES, second-generation DES or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of the international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second-generation DES to BMS) and indirect evidence (first-generation DES with BMS and second-generation DES) from the randomized trials. Twenty-one trials comparing all stents types, including 12 866 patients randomly assigned to treatment groups, were analyzed. A significantly lower incidence of ST was noted with the use of second-generation DES as early as 30 days (odds ratio [OR], 0.36; 95% confidence interval [CI], 0.15-0.82) and between 31 days and 1 year (OR, 0.49; 95% CI, 0.30-0.79) when compared with BMS. Second-generation DES was associated with significantly lower incidence of definite ST at 1 year (OR, 0.3; 95% CI, 0.11-0.83) and myocardial infarction (OR, 0.3; 95% CI, 0.17-0.54) and target vessel revascularization at 1 year (OR, 0.54; 95% CI, 0.80-0.98) when compared with BMS. There was no difference in mortality at 30 days (OR, 0.84; 95% CI, 0.45-1.59) or 1 year (OR, 0.80; 95% CI, 0.56-1.14) with the use of second-generation DES versus BMS. The small number of events may influence the precision of the analysis. Conclusions-Network meta-analysis of randomized trials of primary percutaneous coronary intervention demonstrated lower incidence of ST, myocardial infarction, and target vessel revascularization with second-generation DES when compared with BMS. The use of second-generation DES for percutaneous coronary intervention in ST-segment-elevation myocardial infarction was not associated with adverse events when compared with BMS.
AB - Background-The relative safety of drug-eluting stents (DESs) and bare-metal stents (BMSs) with respect to stent thrombosis (ST) continues to be debated. There are limited data comparing safety and efficacy of second-generation DES to BMS. We compared the clinical outcomes between second-generation DES and BMS for primary percutaneous coronary intervention using network meta-analysis. Methods and Results-Randomized controlled trials comparing stent types (first-generation DES, second-generation DES or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of the international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second-generation DES to BMS) and indirect evidence (first-generation DES with BMS and second-generation DES) from the randomized trials. Twenty-one trials comparing all stents types, including 12 866 patients randomly assigned to treatment groups, were analyzed. A significantly lower incidence of ST was noted with the use of second-generation DES as early as 30 days (odds ratio [OR], 0.36; 95% confidence interval [CI], 0.15-0.82) and between 31 days and 1 year (OR, 0.49; 95% CI, 0.30-0.79) when compared with BMS. Second-generation DES was associated with significantly lower incidence of definite ST at 1 year (OR, 0.3; 95% CI, 0.11-0.83) and myocardial infarction (OR, 0.3; 95% CI, 0.17-0.54) and target vessel revascularization at 1 year (OR, 0.54; 95% CI, 0.80-0.98) when compared with BMS. There was no difference in mortality at 30 days (OR, 0.84; 95% CI, 0.45-1.59) or 1 year (OR, 0.80; 95% CI, 0.56-1.14) with the use of second-generation DES versus BMS. The small number of events may influence the precision of the analysis. Conclusions-Network meta-analysis of randomized trials of primary percutaneous coronary intervention demonstrated lower incidence of ST, myocardial infarction, and target vessel revascularization with second-generation DES when compared with BMS. The use of second-generation DES for percutaneous coronary intervention in ST-segment-elevation myocardial infarction was not associated with adverse events when compared with BMS.
KW - Percutaneous coronary intervention
UR - http://www.scopus.com/inward/record.url?scp=84900451720&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84900451720&partnerID=8YFLogxK
U2 - 10.1161/CIRCINTERVENTIONS.113.000412
DO - 10.1161/CIRCINTERVENTIONS.113.000412
M3 - Article
C2 - 24280964
AN - SCOPUS:84900451720
VL - 7
SP - 49
EP - 61
JO - Circulation: Cardiovascular Interventions
JF - Circulation: Cardiovascular Interventions
SN - 1941-7640
IS - 1
ER -