TY - JOUR
T1 - Simultaneous LC–MS/MS analysis of simvastatin, atorvastatin, rosuvastatin and their active metabolites for plasma samples of obese patients underwent gastric bypass surgery
AU - El-Zailik, Asma
AU - Cheung, Lily K.
AU - Wang, Yang
AU - Sherman, Vadim
AU - Chow, Diana S.L.
N1 - Copyright © 2018 Elsevier B.V. All rights reserved.
PY - 2019/2/5
Y1 - 2019/2/5
N2 - Statins, HMG-CoA reductase inhibitors, are considered the first line treatment of hyperlipidemia to reduce the risk of atherosclerotic cardiovascular diseases. The prevalence of hyperlipidemia and the risk of atherosclerotic cardiovascular diseases are higher in obese patients. Published methods for the quantification of statins and their active metabolites did not test for matrix effect of or validate the method in hyperlipidemic plasma. A sensitive, specific, accurate, and reliable LC–MS/MS method for the simultaneous quantification of simvastatin (SMV), active metabolite of simvastatin acid (SMV-A), atorvastatin (ATV), active metabolites of 2-hydroxy atorvastatin (2-OH-ATV), 4-hydroxy atorvastatin (4-OH-ATV), and rosuvastatin (RSV) was developed and validated in plasma with low (52–103 mg/dl, <300 mg/dl) and high (352–403 mg/dl, >300 mg/dl) levels of triglyceride. The column used in this method was ACQUITY UPLC BEH C18 column (2.1 × 100 mm I.D., 1.7 μm). A gradient elution of mobile phase A (10 mM ammonium formate and 0.04% formic acid in water) and mobile phase B (acetonitrile) was used with a flow rate of 0.4 ml/min and run time of 5 min. The transitions of m/z 436.3 → 285.2 for SMV, m/z 437.2 → 303.2 for SMV-A, m/z 559.2 → 440.3 for ATV, m/z 575.4 → 440.3 for 2-OH-ATV and 4-OH-ATV, m/z 482.3 → 258.1 for RSV, and m/z 412.3 → 224.2 for fluvastatin (internal standard, IS) were determined by Selected Reaction Monitoring (SRM) method to detect transitions ions in the positive ion mode. The assay has a linear range of 0.25 (LLOQ) −100 ng/ml for all six analytes. Accuracy (87–114%), precision (3–13%), matrix effect (92–110%), and extraction recovery (88–100%) of the assay were within the 15% acceptable limit of FDA Guidelines in variations for plasma with both low and high triglyceride levels. The method was used successfully for the quantification of SMV, ATV, RSV, and their active metabolites in human plasma samples collected for an ongoing clinical pharmacokinetic and pharmacodynamic study on patients prior to and post gastric bypass surgery (GBS).
AB - Statins, HMG-CoA reductase inhibitors, are considered the first line treatment of hyperlipidemia to reduce the risk of atherosclerotic cardiovascular diseases. The prevalence of hyperlipidemia and the risk of atherosclerotic cardiovascular diseases are higher in obese patients. Published methods for the quantification of statins and their active metabolites did not test for matrix effect of or validate the method in hyperlipidemic plasma. A sensitive, specific, accurate, and reliable LC–MS/MS method for the simultaneous quantification of simvastatin (SMV), active metabolite of simvastatin acid (SMV-A), atorvastatin (ATV), active metabolites of 2-hydroxy atorvastatin (2-OH-ATV), 4-hydroxy atorvastatin (4-OH-ATV), and rosuvastatin (RSV) was developed and validated in plasma with low (52–103 mg/dl, <300 mg/dl) and high (352–403 mg/dl, >300 mg/dl) levels of triglyceride. The column used in this method was ACQUITY UPLC BEH C18 column (2.1 × 100 mm I.D., 1.7 μm). A gradient elution of mobile phase A (10 mM ammonium formate and 0.04% formic acid in water) and mobile phase B (acetonitrile) was used with a flow rate of 0.4 ml/min and run time of 5 min. The transitions of m/z 436.3 → 285.2 for SMV, m/z 437.2 → 303.2 for SMV-A, m/z 559.2 → 440.3 for ATV, m/z 575.4 → 440.3 for 2-OH-ATV and 4-OH-ATV, m/z 482.3 → 258.1 for RSV, and m/z 412.3 → 224.2 for fluvastatin (internal standard, IS) were determined by Selected Reaction Monitoring (SRM) method to detect transitions ions in the positive ion mode. The assay has a linear range of 0.25 (LLOQ) −100 ng/ml for all six analytes. Accuracy (87–114%), precision (3–13%), matrix effect (92–110%), and extraction recovery (88–100%) of the assay were within the 15% acceptable limit of FDA Guidelines in variations for plasma with both low and high triglyceride levels. The method was used successfully for the quantification of SMV, ATV, RSV, and their active metabolites in human plasma samples collected for an ongoing clinical pharmacokinetic and pharmacodynamic study on patients prior to and post gastric bypass surgery (GBS).
KW - Atorvastatin and metabolites
KW - Hyperlipidemic plasma
KW - LC–MS/MS
KW - Obese subjects from GBS
KW - Rosuvastatin
KW - Simvastatin and metabolite
UR - http://www.scopus.com/inward/record.url?scp=85055888272&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055888272&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2018.10.045
DO - 10.1016/j.jpba.2018.10.045
M3 - Article
C2 - 30396053
AN - SCOPUS:85055888272
SN - 0731-7085
VL - 164
SP - 258
EP - 267
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
ER -