TY - JOUR
T1 - Retrograde coronary venous ethanol infusion for ablation of refractory ventricular tachycardia
AU - Kreidieh, Bahij
AU - Rodríguez-Mañero, Moisés
AU - Schurmann, Paul A.
AU - Ibarra-Cortez, Sergio Hugo
AU - Dave, Amish S.
AU - Valderrábano, Miguel
N1 - Funding Information:
M.V. is supported by NIH/NHLBI R01 HL115003 and the Charles Burnett endowment. M.R.M. was supported by the Antonio Pacifico, MD fellowship grant.
Publisher Copyright:
© 2016 American Heart Association, Inc.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Background - Radiofrequency ablation (RFA) of ventricular tachycardia (VT) can fail because of inaccessibility to the VT substrate. Transarterial coronary ethanol ablation can be effective but entails arterial instrumentation risk. We hypothesized that retrograde coronary venous ethanol ablation can be an alternative bail-out approach to failed VT RFA. Methods and Results - Out of 334 consecutive patients undergoing VT/premature ventricular contraction ablation, 7 patients underwent retrograde coronary venous ethanol ablation. Six out of 7 patients had failed RFA attempts (including epicardial in 3). Coronary venogram-guided venous mapping was performed using a 4F quadripolar catheter or an alligator-clip-connected angioplasty wire. Targeted veins included those with early presystolic potentials and pace-maps matching VT/premature ventricular contraction. An angioplasty balloon (1.5-2×6 mm) was used to deliver 1 to 4 cc of 98% ethanol into a septal branch of the anterior interventricular vein in 5 patients with left ventricular summit VT, a septal branch of the middle cardiac vein, and a posterolateral coronary vein (n=1 each). The clinical VT was successfully ablated acutely in all patients. There were no complications of retrograde coronary venous ethanol ablation, but 1 patient developed pericardial and pleural effusion attributed to pericardial instrumentation. On follow-up of 590±722 days, VT recurred in 4 out of 7 patients, 3 of whom were successfully reablated with RFA. Conclusions - Retrograde coronary venous ethanol ablation is safe and feasible as a bail-out approach to failed VT RFA, particularly those originating from the left ventricular summit.
AB - Background - Radiofrequency ablation (RFA) of ventricular tachycardia (VT) can fail because of inaccessibility to the VT substrate. Transarterial coronary ethanol ablation can be effective but entails arterial instrumentation risk. We hypothesized that retrograde coronary venous ethanol ablation can be an alternative bail-out approach to failed VT RFA. Methods and Results - Out of 334 consecutive patients undergoing VT/premature ventricular contraction ablation, 7 patients underwent retrograde coronary venous ethanol ablation. Six out of 7 patients had failed RFA attempts (including epicardial in 3). Coronary venogram-guided venous mapping was performed using a 4F quadripolar catheter or an alligator-clip-connected angioplasty wire. Targeted veins included those with early presystolic potentials and pace-maps matching VT/premature ventricular contraction. An angioplasty balloon (1.5-2×6 mm) was used to deliver 1 to 4 cc of 98% ethanol into a septal branch of the anterior interventricular vein in 5 patients with left ventricular summit VT, a septal branch of the middle cardiac vein, and a posterolateral coronary vein (n=1 each). The clinical VT was successfully ablated acutely in all patients. There were no complications of retrograde coronary venous ethanol ablation, but 1 patient developed pericardial and pleural effusion attributed to pericardial instrumentation. On follow-up of 590±722 days, VT recurred in 4 out of 7 patients, 3 of whom were successfully reablated with RFA. Conclusions - Retrograde coronary venous ethanol ablation is safe and feasible as a bail-out approach to failed VT RFA, particularly those originating from the left ventricular summit.
KW - LV summit
KW - catheter ablation
KW - ethanol
KW - premature ventricular contractions
KW - tachycardia, ventricular
UR - http://www.scopus.com/inward/record.url?scp=84978876977&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84978876977&partnerID=8YFLogxK
U2 - 10.1161/CIRCEP.116.004352
DO - 10.1161/CIRCEP.116.004352
M3 - Article
C2 - 27406606
AN - SCOPUS:84978876977
SN - 1941-3149
VL - 9
JO - Circulation: Arrhythmia and Electrophysiology
JF - Circulation: Arrhythmia and Electrophysiology
IS - 7
ER -