TY - JOUR
T1 - Quantitative evaluation of protein expression as a function of tissue microarray core diameter
T2 - Is a large (1.5 mm) core better than a small (0.6 mm) core?
AU - Anagnostou, Valsamo K.
AU - Lowery, Frank J.
AU - Syrigos, Konstantinos N.
AU - Cagle, Philip T.
AU - Rimm, David L.
PY - 2010/4/1
Y1 - 2010/4/1
N2 - Context.-Tissue microarrays (TMAs) have emerged as a high-throughput technology for protein evaluation in large cohorts. This technique allows maximization of tissue resources by analysis of sections from 0.6-mm to 1.5-mm core "biopsies" of standard formalin-fixed, paraffin-embedded tissue blocks and by the processing of hundreds of cases arrayed on a single recipient block in an identical manner. Objective.-To assess the expression of a series of biomarkers as a function of core size. Although pathologists frequently feel better if larger core sizes are used, there is no evidence in the literature showing that large cores are better (or worse) than small cores for assessment of TMAs. Design.-Estrogen receptor, HER2/neu, epidermal growth factor receptor, STAT3, mTOR, and phospho-p70 S6 kinase were measured by immunofluorescence with automated quantitative analysis. One random 0.6-mm field (one 0.6-mm spot) was compared to 6 to 12 fields per spot, representing 1-mm and 1.5-mm cores, for 3 different tumor types. Results.-We show that measurement of a single random 0.6-mm spot was comparable to analysis of the whole 1-mm or 1.5-mm spot (Pearson R coefficient varying from 0.87-0.98) for all markers tested. Conclusions.-Since TMA technology is now being used in all phases of biomarker development, this work shows that TMAs with 0.6-mm cores are as representative as those with any common larger core size for optimization of standardized experimental conditions. Given that a greater number of 0.6-cores can be arrayed in a single master block, use of this core size allows increased throughput and decreased cost.
AB - Context.-Tissue microarrays (TMAs) have emerged as a high-throughput technology for protein evaluation in large cohorts. This technique allows maximization of tissue resources by analysis of sections from 0.6-mm to 1.5-mm core "biopsies" of standard formalin-fixed, paraffin-embedded tissue blocks and by the processing of hundreds of cases arrayed on a single recipient block in an identical manner. Objective.-To assess the expression of a series of biomarkers as a function of core size. Although pathologists frequently feel better if larger core sizes are used, there is no evidence in the literature showing that large cores are better (or worse) than small cores for assessment of TMAs. Design.-Estrogen receptor, HER2/neu, epidermal growth factor receptor, STAT3, mTOR, and phospho-p70 S6 kinase were measured by immunofluorescence with automated quantitative analysis. One random 0.6-mm field (one 0.6-mm spot) was compared to 6 to 12 fields per spot, representing 1-mm and 1.5-mm cores, for 3 different tumor types. Results.-We show that measurement of a single random 0.6-mm spot was comparable to analysis of the whole 1-mm or 1.5-mm spot (Pearson R coefficient varying from 0.87-0.98) for all markers tested. Conclusions.-Since TMA technology is now being used in all phases of biomarker development, this work shows that TMAs with 0.6-mm cores are as representative as those with any common larger core size for optimization of standardized experimental conditions. Given that a greater number of 0.6-cores can be arrayed in a single master block, use of this core size allows increased throughput and decreased cost.
UR - http://www.scopus.com/inward/record.url?scp=77950531020&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950531020&partnerID=8YFLogxK
M3 - Article
C2 - 20367312
AN - SCOPUS:77950531020
SN - 0003-9985
VL - 134
SP - 613
EP - 619
JO - Archives of Pathology and Laboratory Medicine
JF - Archives of Pathology and Laboratory Medicine
IS - 4
ER -