TY - JOUR
T1 - Pulsed vacuum and etching systems
T2 - Theoretical design considerations for a pulsed vacuum system and its application to XeF2 etching of Si
AU - Mousavi, Arash Kheyraddini
AU - Abbas, Khawar
AU - Elahi, Mirza Mohammad Mahbube
AU - Lima, Edidson
AU - Moya, Stephen
AU - Butner, Joseph Daniel
AU - Piñon, Denise
AU - Benga, Adeeko
AU - Mousavi, Behnam Kheyraddini
AU - Leseman, Zayd Chad
N1 - Funding Information:
Experiments performed were supported by the Office of Basic Energy Sciences, Division of Materials Sciences and Engineering Experimental Program to Stimulate Competitive Research (EPSCoR) under Award# DE - FG02 - 10ER46720 . DP acknowledges support from the National Science Foundation, USA – Nano Undergraduate Education program Award 1042062 .
PY - 2014/11
Y1 - 2014/11
N2 - Rekindled interest has developed in pulsed vacuum systems due to their use for Xenon Difluoride (XeF2) etching systems and their usefulness in the fabrication of MEMS and nanostructures. Despite numerous applications of pulsed vacuum systems, little information is available in the literature on their design considerations. In this paper mathematical models and their experimental verification are presented for various important design considerations of pulsed vacuum systems. Control of the chambers' pressures and pulse durations are typically the most important design considerations for processes involving pulsed vacuum systems. Pressure sensors give the exact pressure, but accurate chamber volumes are unknown. Thus a methodology is developed for accurate determination of chamber volumes that involves the introduction of a calibrated volume into a chamber. Then it is demonstrated that allowing a known pressure and volume of gas to move between two chambers leads to accurate temporal control of the chambers' pressures. Furthermore, by varying chambers' volumes, configurations, pressures, and the conductances between the chambers it is shown that the pulse duration could be accurately controlled. Though the model and demonstrations are presented in the context of a pulsed XeF2 etching system, they are general and useful for all pulsed vacuum systems.
AB - Rekindled interest has developed in pulsed vacuum systems due to their use for Xenon Difluoride (XeF2) etching systems and their usefulness in the fabrication of MEMS and nanostructures. Despite numerous applications of pulsed vacuum systems, little information is available in the literature on their design considerations. In this paper mathematical models and their experimental verification are presented for various important design considerations of pulsed vacuum systems. Control of the chambers' pressures and pulse durations are typically the most important design considerations for processes involving pulsed vacuum systems. Pressure sensors give the exact pressure, but accurate chamber volumes are unknown. Thus a methodology is developed for accurate determination of chamber volumes that involves the introduction of a calibrated volume into a chamber. Then it is demonstrated that allowing a known pressure and volume of gas to move between two chambers leads to accurate temporal control of the chambers' pressures. Furthermore, by varying chambers' volumes, configurations, pressures, and the conductances between the chambers it is shown that the pulse duration could be accurately controlled. Though the model and demonstrations are presented in the context of a pulsed XeF2 etching system, they are general and useful for all pulsed vacuum systems.
KW - Analytical modeling
KW - Calibration
KW - Dynamic modeling
KW - Pulsed vacuum
UR - http://www.scopus.com/inward/record.url?scp=84907314407&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907314407&partnerID=8YFLogxK
U2 - 10.1016/j.vacuum.2014.07.028
DO - 10.1016/j.vacuum.2014.07.028
M3 - Article
AN - SCOPUS:84907314407
VL - 109
SP - 216
EP - 222
JO - Vacuum
JF - Vacuum
SN - 0042-207X
ER -