TY - JOUR
T1 - Outflow cannula alignment in continuous flow left ventricular devices is associated with stroke
AU - Kassi, Mahwash
AU - Agrawal, Tanushree
AU - Xu, Jiaqiong
AU - Marcos-Abdala, Hernan Gerardo
AU - Araujo-Gutierrez, Raquel
AU - Macgillivray, Thomas
AU - Suarez, Erik E.
AU - Yousefzai, Rayan
AU - Fida, Nadia
AU - Kim, Ju H.
AU - Hussain, Imad
AU - Guha, Ashrith
AU - Trachtenberg, Barry
AU - Bhimaraj, Arvind
AU - Chang, Su Min
AU - Estep, Jerry
N1 - Publisher Copyright:
© The Author(s) 2023.
PY - 2023/4
Y1 - 2023/4
N2 - We sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The primary outcome was stroke within 1 year of LVAD implantation. Of the 101 patients that underwent LVAD Implantation and cardiac CT scan during the study period, 78 met inclusion criteria. The primary outcome occurred in 12 (15.4%) patients with a median time to stroke of 77 days (interquartile range: 42–132 days). Of these, 10 patients had an ischemic and two had hemorrhagic strokes. The predominant device type was Heart Mate II (94.8%). Patients with LVAD outflow cannula to aortic angle lesser than 37.5° and those with outflow graft diameter of anastomosis less than 1.5 cm (assessed by cardiac CT) had significantly higher stroke risk (p < 0.001 and p = 0.01 respectively). In HMII patients, a lower LVAD speed at the time of CT scan was associated with stroke. Further studies are needed to identify optimal outflow graft configuration to mitigate stroke risk.
AB - We sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The primary outcome was stroke within 1 year of LVAD implantation. Of the 101 patients that underwent LVAD Implantation and cardiac CT scan during the study period, 78 met inclusion criteria. The primary outcome occurred in 12 (15.4%) patients with a median time to stroke of 77 days (interquartile range: 42–132 days). Of these, 10 patients had an ischemic and two had hemorrhagic strokes. The predominant device type was Heart Mate II (94.8%). Patients with LVAD outflow cannula to aortic angle lesser than 37.5° and those with outflow graft diameter of anastomosis less than 1.5 cm (assessed by cardiac CT) had significantly higher stroke risk (p < 0.001 and p = 0.01 respectively). In HMII patients, a lower LVAD speed at the time of CT scan was associated with stroke. Further studies are needed to identify optimal outflow graft configuration to mitigate stroke risk.
KW - Outflow cannula, left ventricular devices, stroke
KW - artificial kidney, apheresis, & detoxification techniques
KW - artificial kidney, apheresis, & detoxification techniques, echocardiography, cardiac computed tomography, cardiac imaging
UR - http://www.scopus.com/inward/record.url?scp=85150629435&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85150629435&partnerID=8YFLogxK
U2 - 10.1177/03913988231154284
DO - 10.1177/03913988231154284
M3 - Article
C2 - 36895175
AN - SCOPUS:85150629435
VL - 46
SP - 226
EP - 234
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
SN - 0391-3988
IS - 4
ER -