TY - JOUR
T1 - Outcomes of Durable Mechanical Circulatory Support in Myocarditis
T2 - Analysis of the International Society for Heart and Lung Transplantation Registry for Mechanically Assisted Circulatory Support Registry
AU - Al-Kindi, Sadeer G.
AU - Xie, Rongbing
AU - Kirklin, James K.
AU - Cowger, Jennifer
AU - Oliveira, Guilherme H.
AU - Krabatsch, Thomas
AU - Nakatani, Takeshi
AU - Schueler, Stephan
AU - Leet, Angeline
AU - Golstein, Daniel
AU - Elamm, Chantal A.
N1 - Publisher Copyright:
Copyright ASAIO 2021.
PY - 2022/2/1
Y1 - 2022/2/1
N2 - Myocarditis can be refractory to medical therapy and require durable mechanical circulatory support (MCS). The characteristics and outcomes of these patients are not known. We identified all patients with clinically-diagnosed or pathology-proven myocarditis who underwent mechanical circulatory support in the International Society for Heart and Lung Transplantation Registry for Mechanically Assisted Circulatory Support registry (2013-2016). The characteristics and outcomes of these patients were compared to those of patients with nonischemic cardiomyopathy (NICM). Out of 14,062 patients in the registry, 180 (1.2%) had myocarditis and 6,602 (46.9%) had NICM. Among patients with myocarditis, duration of heart failure was <1 month in 22%, 1-12 months in 22.6%, and >1 year in 55.4%. Compared with NICM, patients with myocarditis were younger (45 vs. 52 years, P < 0.001) and were more often implanted with Interagency Registry for Mechanically Assisted Circulatory Support profile 1 (30% vs. 15%, P < 0.001). Biventricular mechanical support (biventricular ventricular assist device [BIVAD] or total artificial heart) was implanted more frequently in myocarditis (18% vs. 6.7%, P < 0.001). Overall postimplant survival was not different between myocarditis and NICM (left ventricular assist device: P = 0.27, BIVAD: P = 0.50). The proportion of myocarditis patients that have recovered by 12 months postimplant was significantly higher in myocarditis compared to that of NICM (5% vs. 1.7%, P = 0.0003). Adverse events (bleeding, infection, and neurologic dysfunction) were all lower in the myocarditis than NICM. In conclusion, although myocarditis patients who receive durable MCS are sicker preoperatively with higher needs for biventricular MCS, their overall MCS survival is noninferior to NICM. Patients who received MCS for myocarditis are more likely than NICM to have MCS explanted due to recovery, however, the absolute rates of recovery were low.
AB - Myocarditis can be refractory to medical therapy and require durable mechanical circulatory support (MCS). The characteristics and outcomes of these patients are not known. We identified all patients with clinically-diagnosed or pathology-proven myocarditis who underwent mechanical circulatory support in the International Society for Heart and Lung Transplantation Registry for Mechanically Assisted Circulatory Support registry (2013-2016). The characteristics and outcomes of these patients were compared to those of patients with nonischemic cardiomyopathy (NICM). Out of 14,062 patients in the registry, 180 (1.2%) had myocarditis and 6,602 (46.9%) had NICM. Among patients with myocarditis, duration of heart failure was <1 month in 22%, 1-12 months in 22.6%, and >1 year in 55.4%. Compared with NICM, patients with myocarditis were younger (45 vs. 52 years, P < 0.001) and were more often implanted with Interagency Registry for Mechanically Assisted Circulatory Support profile 1 (30% vs. 15%, P < 0.001). Biventricular mechanical support (biventricular ventricular assist device [BIVAD] or total artificial heart) was implanted more frequently in myocarditis (18% vs. 6.7%, P < 0.001). Overall postimplant survival was not different between myocarditis and NICM (left ventricular assist device: P = 0.27, BIVAD: P = 0.50). The proportion of myocarditis patients that have recovered by 12 months postimplant was significantly higher in myocarditis compared to that of NICM (5% vs. 1.7%, P = 0.0003). Adverse events (bleeding, infection, and neurologic dysfunction) were all lower in the myocarditis than NICM. In conclusion, although myocarditis patients who receive durable MCS are sicker preoperatively with higher needs for biventricular MCS, their overall MCS survival is noninferior to NICM. Patients who received MCS for myocarditis are more likely than NICM to have MCS explanted due to recovery, however, the absolute rates of recovery were low.
KW - left ventricular assist device
KW - mechanical circulatory support
KW - myocarditis
KW - outcomes
KW - total artificial heart
UR - http://www.scopus.com/inward/record.url?scp=85119006870&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119006870&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000001430
DO - 10.1097/MAT.0000000000001430
M3 - Article
C2 - 33769352
AN - SCOPUS:85119006870
SN - 1058-2916
VL - 68
SP - 190
EP - 196
JO - ASAIO Journal
JF - ASAIO Journal
IS - 2
ER -