Skip to main navigation Skip to search Skip to main content

Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy

Yuting Li, Rachael M. Martin-Paulpeter, Christine V. Chung, Miguel A. Aguilar, Carlos A. Matias, Adrian Delgado, Saurabh S. Nair, Laurence E. Court, Luis Perles, Narayan Sahoo, Ronald X. Zhu, Falk Poenisch, David B. Flint, Gabriel O. Sawakuchi, Sam Beddar, Eugene Koay, Jamie S. Baker, Ethan B. Ludmir, Joshua S. Niedzielski

Research output: Contribution to journalArticlepeer-review

Abstract

Background – Spatially fractionated radiotherapy (SFRT) delivered as lattice radiotherapy (LRT) creates high-dose ‘vertex’ subvolumes (VTVH) embedded within low-dose ‘valley’ regions (VTVL) to intensify intratumoral dose while minimizing radiation dose and toxicity to organs at risk (OARs). We developed a pencil-beam scanning (PBS) intensity modulated proton therapy (IMPT) LRT planning approach and dosimetrically compared it directly with contemporary photon-based volume modulated arc therapy (VMAT) LRT for liver cancer with bulky tumors. Methods – Twenty-one retrospective liver cases were replanned in RayStation to a single fraction of 20 Gy to VTVH with explicit VTVL sparing (mean dose <5Gy). Primary dosimetric endpoints were VTVH D80 and VTVL mean dose (analogous to mean valley dose), with secondary endpoints of VTVH/VTVL ratios (PVDR-like metrics at D80/D90/D100), VTVL D5/D80, GTV D10/D90, and planning risk volume (PRV) 0.03 cm³ hotspots. Statistical analysis consisted of paired tests (t-test or Wilcoxon signed-rank) after assessing data normality (Shapiro-Wilk tests) and using α=0.05 for significance. Results – Compared with photon VMAT-LRT, IMPT-LRT significantly reduced VTVL mean dose (p<0.00001) and increased VTVH D80 (p<0.00001), yielding higher VTVH/VTVL ratios at D80/D90/D100 (all p<0.00001). Gross tumor volume (GTV) heterogeneity (D20/D80) significantly increased with proton-LRT (p<0.00001) and OAR hot-spot metrics (PRV D0.03cc) were comparable between both modalities (p=0.71). Conclusions – A robust PBS proton-LRT planning approach was developed and compared to photon VMAT-LRT for large liver tumors. Our IMPT-LRT approach maximizes peak-to-valley separation and simultaneously maintains target coverage while significantly reducing valley dose, as compared to traditional VMAT-LRT. These findings support future prospective clinical evaluation.

Original languageEnglish (US)
Article number1731259
Pages (from-to)1-10
Number of pages10
JournalFrontiers in Oncology
Volume15
DOIs
StatePublished - Apr 2 2026

Keywords

  • VMAT
  • bulky tumor
  • hepatocellular carcinoma
  • lattice radiation therapy
  • liver cancer
  • peak-to-valley dose ratio
  • proton therapy
  • spatially fractionated radiation therapy

ASJC Scopus subject areas

  • Oncology
  • Cancer Research

Fingerprint

Dive into the research topics of 'Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy'. Together they form a unique fingerprint.

Cite this