TY - JOUR
T1 - Interferon-γ release assays and tuberculin skin testing for diagnosis of latent tuberculosis infection in healthcare workers in the united states
AU - Dorman, Susan E.
AU - Belknap, Robert
AU - Graviss, Edward A.
AU - Reves, Randall
AU - Schluger, Neil
AU - Weinfurter, Paul
AU - Wang, Yaping
AU - Cronin, Wendy
AU - Hirsch-Moverman, Yael
AU - Teeter, Larry D.
AU - Parker, Matthew
AU - Garrett, Denise O.
AU - Daley, Charles L.
PY - 2014/1/1
Y1 - 2014/1/1
N2 - Rationale: IFN-γ release assays (IGRAs) are alternatives to tuberculin skin testing (TST) for diagnosis of latent tuberculosis infection. Limited data suggest IGRAs may not perform well for serial testing of healthcare workers (HCWs). Objectives: Determine the performance characteristics of IGRAs versus TST for serial testing of HCWs. Methods: A longitudinal study involving 2,563 HCWs undergoing occupational tuberculosis screening at four healthcare institutions in the United States, where the average tuberculosis case rate ranged from 4 to 9 per 100,000 persons. QuantiFERON-TB Gold In-Tube (QFTGIT), T-SPOT.TB (T-SPOT), and TST were performed at baseline and every 6 months for 18 months between February 2008 and March 2011. Measurements and Main Results: A total of 2,418 HCWs completed baseline testing, which was positive for 125 (5.2%) by TST, 118 (4.9%) by QFT-GIT, and 144 (6.0%) by T-SPOT. A baseline positive TST with negative IGRAs was associated with bacillus Calmette-Gúerin (BCG) vaccination (odds ratio: 25.1 [95% confidence interval: 15.5, 40.5] vs. no BCG). Proportions of participants with test conversion during the study period were 138 of 2,263 (6.1%) for QFT-GIT, 177 of 2,137 (8.3%) for T-SPOT, and 21 of 2,293 (0.9%) for TST (P < 0.001 for QFT-GIT vs. TST and for T-SPOT vs. TST; P = 0.005 for QFT-GIT vs. T-SPOT). Of the QFT-GIT and T-SPOT converters, 81 of 106 (76.4%) and 91 of 118 (77.1%), respectively, were negative when retested 6 months later. There was negative/positive discordance for 15 of 170 (8.8%) participants by QFT-GIT and for 19 of 151 (12.6%) by T-SPOT when blood was drawn 2 weeks later. Conclusions: Most conversions among HCWs in low TB incidence settings appear to be false positives, and these occurred six to nine times more frequently with IGRAs than TST; repeat testing of apparent converters is warranted.
AB - Rationale: IFN-γ release assays (IGRAs) are alternatives to tuberculin skin testing (TST) for diagnosis of latent tuberculosis infection. Limited data suggest IGRAs may not perform well for serial testing of healthcare workers (HCWs). Objectives: Determine the performance characteristics of IGRAs versus TST for serial testing of HCWs. Methods: A longitudinal study involving 2,563 HCWs undergoing occupational tuberculosis screening at four healthcare institutions in the United States, where the average tuberculosis case rate ranged from 4 to 9 per 100,000 persons. QuantiFERON-TB Gold In-Tube (QFTGIT), T-SPOT.TB (T-SPOT), and TST were performed at baseline and every 6 months for 18 months between February 2008 and March 2011. Measurements and Main Results: A total of 2,418 HCWs completed baseline testing, which was positive for 125 (5.2%) by TST, 118 (4.9%) by QFT-GIT, and 144 (6.0%) by T-SPOT. A baseline positive TST with negative IGRAs was associated with bacillus Calmette-Gúerin (BCG) vaccination (odds ratio: 25.1 [95% confidence interval: 15.5, 40.5] vs. no BCG). Proportions of participants with test conversion during the study period were 138 of 2,263 (6.1%) for QFT-GIT, 177 of 2,137 (8.3%) for T-SPOT, and 21 of 2,293 (0.9%) for TST (P < 0.001 for QFT-GIT vs. TST and for T-SPOT vs. TST; P = 0.005 for QFT-GIT vs. T-SPOT). Of the QFT-GIT and T-SPOT converters, 81 of 106 (76.4%) and 91 of 118 (77.1%), respectively, were negative when retested 6 months later. There was negative/positive discordance for 15 of 170 (8.8%) participants by QFT-GIT and for 19 of 151 (12.6%) by T-SPOT when blood was drawn 2 weeks later. Conclusions: Most conversions among HCWs in low TB incidence settings appear to be false positives, and these occurred six to nine times more frequently with IGRAs than TST; repeat testing of apparent converters is warranted.
KW - False positive
KW - QuantiFERON
KW - Screening
KW - T-SPOT.TB
UR - http://www.scopus.com/inward/record.url?scp=84891859082&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84891859082&partnerID=8YFLogxK
U2 - 10.1164/rccm.201302-0365OC
DO - 10.1164/rccm.201302-0365OC
M3 - Article
AN - SCOPUS:84891859082
SN - 1073-449X
VL - 189
SP - 77
EP - 87
JO - American journal of respiratory and critical care medicine
JF - American journal of respiratory and critical care medicine
IS - 1
ER -