T1 - Inflammatory response after implantation of a left ventricular assist device
T2 - Comparison between the axial flow MicroMed DeBakey VAD and the pulsatile novacor device
AU - Loebe, Matthias
AU - Koster, Andreas
AU - Sänger, Stefan
AU - Potapov, Evgenij V.
AU - Kuppe, Hermann
AU - Noon, George P.
AU - Hetzer, Roland
PY - 2001/1/1
Y1 - 2001/1/1
N2 - The implantation of a ventricular assist device (VAD) is associated with a stimulation of the inflammatory system. We compared changes in the inflammatory response after implantation of a pulsatile Novacor left (L) VAD and the axial flow MicroMed DeBakey VAD. Six consecutive patients after implantation of a Novacor LVAD (NC) and six patients after implantation of a MicroMed DeBakey VAD (MD) were included in the investigation. Patients received LVADs for medically non treatable end-stage heart failure. Tumor necrosis factor alpha (TNF), C3a, C5a, interleukin 6 (IL-6), and neutrophil elastase were measured twice a week over a period of 3 months after implantation of the device. All tests were performed with an enzyme-linked immunosorbent assay. There was no significant difference in the clinical course of the two groups. All inflammatory parameters were elevated in both groups during the entire period of the investigation. There was no difference in TNF, polynuclear leukocyte elastase, or C3a levels between the two groups; however, IL-6 (NC: 23.6 ± 37.6 pg/ml vs. MD: 63 ± 114 pg/ml, p < 0.001) and C5a (NC: 708 ± 352 μg/L vs. MD: 1,745 ± 1,305 μg/L, p < 0.001) were increased significantly more in patients following implantation of the axial flow MicroMed DeBakey VAD. Compared with the pulsatile Novacor device, the implantation of the axial flow MicroMed DeBakey LVAD seems to be associated with an increased stimulation of one part of the inflammatory system. Further investigations are necessary for evaluation of the pathophysiologic mechanism and clinical implications of these findings.
AB - The implantation of a ventricular assist device (VAD) is associated with a stimulation of the inflammatory system. We compared changes in the inflammatory response after implantation of a pulsatile Novacor left (L) VAD and the axial flow MicroMed DeBakey VAD. Six consecutive patients after implantation of a Novacor LVAD (NC) and six patients after implantation of a MicroMed DeBakey VAD (MD) were included in the investigation. Patients received LVADs for medically non treatable end-stage heart failure. Tumor necrosis factor alpha (TNF), C3a, C5a, interleukin 6 (IL-6), and neutrophil elastase were measured twice a week over a period of 3 months after implantation of the device. All tests were performed with an enzyme-linked immunosorbent assay. There was no significant difference in the clinical course of the two groups. All inflammatory parameters were elevated in both groups during the entire period of the investigation. There was no difference in TNF, polynuclear leukocyte elastase, or C3a levels between the two groups; however, IL-6 (NC: 23.6 ± 37.6 pg/ml vs. MD: 63 ± 114 pg/ml, p < 0.001) and C5a (NC: 708 ± 352 μg/L vs. MD: 1,745 ± 1,305 μg/L, p < 0.001) were increased significantly more in patients following implantation of the axial flow MicroMed DeBakey VAD. Compared with the pulsatile Novacor device, the implantation of the axial flow MicroMed DeBakey LVAD seems to be associated with an increased stimulation of one part of the inflammatory system. Further investigations are necessary for evaluation of the pathophysiologic mechanism and clinical implications of these findings.
UR - http://www.scopus.com/inward/record.url?scp=0035013956&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035013956&partnerID=8YFLogxK
U2 - 10.1097/00002480-200105000-00023
DO - 10.1097/00002480-200105000-00023
M3 - Article
C2 - 11374772
AN - SCOPUS:0035013956
SN - 1058-2916
VL - 47
SP - 272
EP - 274
JO - ASAIO Journal
JF - ASAIO Journal
IS - 3
ER -