Imaging of the Left Atrial Appendage before Occluder Device Placement: Evaluation of Virtual Monoenergetic Images in a Single-Bolus Dual-Phase Protocol

Kai Roman Laukamp, Sara Dastmalchian, Yasmeen K. Tandon, Leslie Ciancibello, Lenhard Pennig, Simon Lennartz, Sadeer Al-Kindi, Sanjay Rajagopalan, Kaustav Bera, Nils Große Hokamp, Robert Gilkeson, Amit Gupta

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose Preimplantation cardiac computed tomography (CT) for assessment of the left atrial appendage (LAA) enables correct sizing of the device and the detection of contraindications, such as thrombi. In the arterial phase, distinction between false filling defects and true thrombi can be hampered by insufficient contrast medium distribution. A delayed scan can be used to further differentiate both conditions, but contrast in these acquisitions is relatively lower. In this study, we investigated whether virtual monoenergetic images (VMI) from dual-energy spectral detector CT (SDCT) can be used to enhance contrast and visualization in the delayed phase. Materials and Methods Forty-nine patients receiving SDCT imaging of the LAA were retrospectively enrolled. The imaging protocol comprised dual-phase acquisitions with single-bolus contrast injection. Conventional images (CI) from both phases and 40-keV VMI from the delayed phase were reconstructed. Attenuation, signal-, and contrast-to-noise ratios (SNR/CNR) were calculated by placing regions-of-interest in the LAA, left atrium, and muscular portion of interventricular septum. Two radiologists subjectively evaluated conspicuity and homogeneity of contrast distribution within the LAA. Results Contrast of the LAA decreased significantly in the delayed phase but was significantly improved by VMI, showing comparable attenuation, SNR, and CNR to CI from the arterial phase (attenuation/SNR/CNR, CI arterial phase: 266.0 ± 117.0 HU/14.2 ± 7.2/6.6 ± 3.9; CI-delayed phase: 107.6 ± 35.0 HU/5.9 ± 3.0/1.0 ± 1.0; VMI delayed phase: 260.3 ± 108.6 HU/18.2 ± 10.6/4.8 ± 3.4). The subjective reading confirmed the objective findings showing improved conspicuity and homogeneity in the delayed phase. Conclusions The investigated single-bolus dual-phase acquisition protocol provided improved visualization of the LAA. Homogeneity of contrast media was higher in the delayed phase, while VMI maintained high contrast.

Original languageEnglish (US)
Pages (from-to)735-741
Number of pages7
JournalJournal of Computer Assisted Tomography
Volume46
Issue number5
DOIs
StatePublished - Sep 1 2022

Keywords

  • dual-energy CT
  • left atrial appendage
  • occluder device
  • spectral detector
  • x-ray computed tomography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Imaging of the Left Atrial Appendage before Occluder Device Placement: Evaluation of Virtual Monoenergetic Images in a Single-Bolus Dual-Phase Protocol'. Together they form a unique fingerprint.

Cite this