Abstract
BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown.
AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut.
METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions.
RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth.
CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access.
CLINICALTRIALS: gov: NCT02701283.
| Original language | English (US) |
|---|---|
| Pages (from-to) | E330-E339 |
| Journal | EuroIntervention |
| Volume | 19 |
| Issue number | 4 |
| DOIs | |
| State | Published - Jul 2023 |
Keywords
- TAVI
- aortic stenosis
- valve-in-valve
- Humans
- Heart Valve Prosthesis
- Tomography, X-Ray Computed
- Treatment Outcome
- Prosthesis Design
- Feasibility Studies
- Aortic Valve Stenosis/diagnostic imaging
- Transcatheter Aortic Valve Replacement/methods
- Female
- Aortic Valve/diagnostic imaging
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
Fingerprint
Dive into the research topics of 'Feasibility of redo-TAVI in self-expanding Evolut valves: a CT analysis from the Evolut Low Risk Trial substudy'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS