Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses

Robert J.M. Klautz, Vivek Rao, Michael J. Reardon, G. Michael Deeb, Francois Dagenais, Michael G. Moront, Stephen H. Little, Louis Labrousse, Himanshu J. Patel, Saki Ito, Shuzhen Li, Joseph F. Sabik, Jae K. Oh

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management.

METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated.

RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml.

CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time.

CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.

Original languageEnglish (US)
Article numberezae122
JournalEuropean Journal of Cardio-thoracic Surgery
Volume65
Issue number5
DOIs
StatePublished - May 1 2024

Keywords

  • Aortic valve replacement
  • Surgical aortic bioprostheses
  • Valve haemodynamic performance
  • Echocardiography
  • Humans
  • Heart Valve Prosthesis
  • Middle Aged
  • Bioprosthesis
  • Male
  • Hemodynamics/physiology
  • Prosthesis Design
  • Heart Valve Prosthesis Implantation/methods
  • Aged, 80 and over
  • Aortic Valve/surgery
  • Female
  • Aged

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses'. Together they form a unique fingerprint.

Cite this