Establishing Thromboelastography with Platelet-Function Analyzer Reference Ranges and Other Measures in Healthy Term Pregnant Women

Kathleen M. Antony, Roshanak Mansouri, Melanie Arndt, Shiu Ki Rocky Hui, Purviben Jariwala, Virginia Moreland McMullen, Jun Teruya, Kjersti Aagaard

Research output: Contribution to journalArticlepeer-review

27 Scopus citations

Abstract

Objective The diagnosis of coagulopathy cannot always be performed at point of care. Thromboelastography (TEG) and the platelet-function analyzer (PFA-100), have emerged as reliable means for coagulation analysis. However, their reliable utility in pregnancy remains to be determined. We sought to establish reference values with concomitant determination of other known coagulation measures in nonlaboring gravidae in an effort to report the mean and variance of multiple testing modalities. Study Design Fifty-nine term, nonlaboring, pregnant women without comorbidities were enrolled, either at presentation for scheduled delivery or at presentation to triage for a non-labor-related indication. TEG, PFA-100, and complete coagulation measures of the overall hemostatic function (including prothrombin time, activated partial thromboplastin time, fibrinogen, protein C, protein S, von Willebrand factor antigen, ristocetin cofactor activity, and ADAMTS-13) were performed. Prior investigations of TEG and PFA-100 parameters in normal gravidae were reviewed, and pooled means and standard deviations (as a measure of variance) were calculated. Results TEG and PFA-100 parameters were significantly different among pregnant gravidae compared with nonpregnant reference ranges, and varied in association with other measures of the coagulation system. Our results and the pooled results reflect a hypercoagulable state. Conclusion Our data suggest that TEG values are significantly different in term, nonlaboring, healthy gravidae compared with nonpregnant reference values. Pooled means and standard deviations shown here may be considered for reference.

Original languageEnglish (US)
Pages (from-to)545-553
Number of pages9
JournalAmerican Journal of Perinatology
Volume32
Issue number6
DOIs
StatePublished - May 1 2015

Keywords

  • platelet-function analyzer
  • pregnancy
  • reference values
  • thromboelastography

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Obstetrics and Gynecology

Fingerprint

Dive into the research topics of 'Establishing Thromboelastography with Platelet-Function Analyzer Reference Ranges and Other Measures in Healthy Term Pregnant Women'. Together they form a unique fingerprint.

Cite this