TY - JOUR
T1 - Electroencephalographic source imaging of spikes with concurrent high-frequency oscillations is concordant with the clinical ground truth
AU - Gonsisko, Colton B.
AU - Cai, Zhengxiang
AU - Jiang, Xiyuan
AU - Duque Lopez, Andrea M.
AU - Worrell, Gregory A.
AU - He, Bin
N1 - Publisher Copyright:
© 2024 The Author(s). Epilepsia published by Wiley Periodicals LLC on behalf of International League Against Epilepsy.
PY - 2024/10/10
Y1 - 2024/10/10
N2 - Objective: Epilepsy raises critical challenges to accurately localize the epileptogenic zone (EZ) to guide presurgical planning. Previous research has suggested that interictal spikes overlapping with high-frequency oscillations, referred to here as pSpikes, serve as a reliable biomarker for EZ estimation, but there remains a question as to whether and to how pSpikes perform as compared to other types of epileptic spikes. This study aims to address this question by investigating the source imaging capabilities of pSpikes alongside other spike types. Methods: A total of 2819 interictal spikes from 76-channel scalp electroencephalography (EEG) were analyzed in a cohort of 24 drug-resistant focal epilepsy patients. All patients received surgical resection, and 16 were declared seizure-free based on at least 1 year of postoperative follow-up. A recently developed electrophysiological source imaging algorithm—fast spatiotemporal iteratively reweighted edge sparsity (FAST-IRES)—was used for source imaging of the detected interictal spikes. The performance of 217 pSpikes was compared with 772 nSpikes (spikes with irregular high-frequency activations), 1830 rSpikes (spikes with no high-frequency activity), and all 2819 aSpikes (all interictal spikes). Results: The localization and extent estimation using pSpikes are concordant with the clinical ground truth; using pSpikes yields the best performance compared with nSpikes, rSpikes, and conventional spike imaging (aSpikes). For multiple spike type seizure-free patients, the mean localization error for pSpike imaging was 6.8 mm, compared with 15.0 mm for aSpikes. The sensitivity, precision, and specificity were.41,.67, and.93 for pSpikes compared with.32,.48, and.93 for aSpikes. Significance: These results demonstrate the merits of noninvasive EEG source localization, and that (1) pSpike is a superior biomarker, outperforming conventional spike imaging for the localization of epileptic sources, and especially those with multiple irritative zones; and (2) FAST-IRES provides accurate source estimation that is highly concordant with clinical ground truth, even in situations of single spike analysis with low signal-to-noise ratio.
AB - Objective: Epilepsy raises critical challenges to accurately localize the epileptogenic zone (EZ) to guide presurgical planning. Previous research has suggested that interictal spikes overlapping with high-frequency oscillations, referred to here as pSpikes, serve as a reliable biomarker for EZ estimation, but there remains a question as to whether and to how pSpikes perform as compared to other types of epileptic spikes. This study aims to address this question by investigating the source imaging capabilities of pSpikes alongside other spike types. Methods: A total of 2819 interictal spikes from 76-channel scalp electroencephalography (EEG) were analyzed in a cohort of 24 drug-resistant focal epilepsy patients. All patients received surgical resection, and 16 were declared seizure-free based on at least 1 year of postoperative follow-up. A recently developed electrophysiological source imaging algorithm—fast spatiotemporal iteratively reweighted edge sparsity (FAST-IRES)—was used for source imaging of the detected interictal spikes. The performance of 217 pSpikes was compared with 772 nSpikes (spikes with irregular high-frequency activations), 1830 rSpikes (spikes with no high-frequency activity), and all 2819 aSpikes (all interictal spikes). Results: The localization and extent estimation using pSpikes are concordant with the clinical ground truth; using pSpikes yields the best performance compared with nSpikes, rSpikes, and conventional spike imaging (aSpikes). For multiple spike type seizure-free patients, the mean localization error for pSpike imaging was 6.8 mm, compared with 15.0 mm for aSpikes. The sensitivity, precision, and specificity were.41,.67, and.93 for pSpikes compared with.32,.48, and.93 for aSpikes. Significance: These results demonstrate the merits of noninvasive EEG source localization, and that (1) pSpike is a superior biomarker, outperforming conventional spike imaging for the localization of epileptic sources, and especially those with multiple irritative zones; and (2) FAST-IRES provides accurate source estimation that is highly concordant with clinical ground truth, even in situations of single spike analysis with low signal-to-noise ratio.
KW - electroencephalography
KW - electrophysiological source imaging
KW - high-frequency oscillations
KW - interictal spike
KW - source localization
UR - http://www.scopus.com/inward/record.url?scp=85205890577&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85205890577&partnerID=8YFLogxK
U2 - 10.1111/epi.18141
DO - 10.1111/epi.18141
M3 - Article
AN - SCOPUS:85205890577
SN - 0013-9580
JO - Epilepsia
JF - Epilepsia
ER -