TY - JOUR
T1 - Effect of mechanically expanded vs self-expanding transcatheter aortic valve replacement on mortality and major adverse clinical events in high-risk patients with aortic stenosis the REPRISE III randomized clinical trial
AU - Feldman, Ted E.
AU - Reardon, Michael J.
AU - Rajagopal, Vivek
AU - Makkar, Raj R.
AU - Bajwa, Tanvir K.
AU - Kleiman, Neal S.
AU - Linke, Axel
AU - Kereiakes, Dean J.
AU - Waksman, Ron
AU - Thourani, Vinod H.
AU - Stoler, Robert C.
AU - Mishkel, Gregory J.
AU - Rizik, David G.
AU - Iyer, Vijay S.
AU - Gleason, Thomas G.
AU - Tchétché, Didier
AU - Rovin, Joshua D.
AU - Buchbinder, Maurice
AU - Meredith, Ian T.
AU - Götberg, Matthias
AU - Bjursten, Henrik
AU - Meduri, Christopher
AU - Salinger, Michael H.
AU - Allocco, Dominic J.
AU - Dawkins, Keith D.
N1 - Funding Information:
completed and submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest. Dr Feldman reports receipt of grants and personal fees from Boston Scientific Corp, Abbott, Edwards, and WL Gore. Dr Reardon reports receipt of consulting fees paid to his institution from Medtronic. Dr Rajagopal reports scientific advisory board membership for Boston Scientific Corp and serving as speaker/proctor for Medtronic, Edwards, and Abbott Vascular. Dr Bajwa reports receipt of consulting fees from Medtronic. Dr Kleiman reports provision of educational services for Medtronic. Dr Linke reports receipt of speaker honoraria or consultancy fees for Medtronic, St Jude Medical, Claret Medical, Boston Scientific Corp, Edwards Lifesciences, Symetis, and Bard and stock options ownership from Claret Medical. Dr Kereiakes reports scientific advisory board membership and consultancy for Boston Scientific Corp. Dr Waksman reports receipt of grants/research support or consulting fees/honoraria from Boston Scientific Corp, Biotronik,, Biosensors, Medtronic Vascular, Abbott Vascular, Symetis, Med Alliance, LifeTech, Amgen, and Volcano/Philips. Dr Stoler reports advisory board membership or proctoring for Medtronic and Boston Scientific Corp. Dr Mishkel reports receipt of minor honoraria/travel expenses from Boston Scientific Corp and Edwards Lifesciences for proctoring services. Dr Gleason reports receipt of grant support from Medtronic to his institution. Dr Rovin reports receipt of proctoring and speaking fees from Abbott and Medtronic. Dr Buchbinder reports stock ownership in and scientific advisory board membership and proctoring for Boston Scientific Corp. Dr Meredith reports past or full-time employment by and stock ownership in Boston Scientific Corp. Dr Götberg reports receipt of consulting honoraria and speaking and proctoring fees from Boston Scientific Corp. Dr Meduri reports advisory board membership for Boston Scientific Corp and Mitralign, consultancy for Medtronic, Boston Scientific Corp, and Mitralign, receipt of educational grants from Medtronic and Edwards, and proctoring for Edwards, Medtronic, Boston Scientific Corp, and Mitralign. Dr Salinger reports receipts of payments/travel expenses for proctoring services, advisory board consulting, and classroom teaching from Boston Scientific Corp and payments for proctoring services/travel expenses and speaking from Edwards Lifesciences. Drs Allocco and Dawkins report past or full-time employment by and stock ownership in Boston Scientific Corp. No other disclosures were reported.
Publisher Copyright:
© 2018 American Medical Association. All rights reserved.
PY - 2018/1/2
Y1 - 2018/1/2
N2 - Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur.Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR.Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017.Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305).Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set.Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%).Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients.Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.
AB - Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur.Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR.Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017.Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305).Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set.Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%).Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients.Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.
KW - Aged
KW - Aged, 80 and over
KW - Aortic Valve/surgery
KW - Aortic Valve Stenosis/mortality
KW - Bioprosthesis
KW - Cardiovascular Diseases/etiology
KW - Female
KW - Follow-Up Studies
KW - Heart Valve Prosthesis
KW - Humans
KW - Male
KW - Postoperative Complications/etiology
KW - Prosthesis Design
KW - Risk Factors
KW - Transcatheter Aortic Valve Replacement/adverse effects
KW - Treatment Outcome
UR - http://www.scopus.com/inward/record.url?scp=85040240090&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85040240090&partnerID=8YFLogxK
U2 - 10.1001/jama.2017.19132
DO - 10.1001/jama.2017.19132
M3 - Article
C2 - 29297076
AN - SCOPUS:85040240090
SN - 0098-7484
VL - 319
SP - 27
EP - 37
JO - JAMA - Journal of the American Medical Association
JF - JAMA - Journal of the American Medical Association
IS - 1
ER -