TY - JOUR
T1 - Effect of a sustained difference in hemodialytic clearance on the plasma levels of p-cresol sulfate and indoxyl sulfate
AU - Camacho, Orlando
AU - Rosales, Maria Carmela
AU - Shafi, Tariq
AU - Fullman, Jonathan
AU - Plummer, Natalie S.
AU - Meyer, Timothy W.
AU - Sirich, Tammy L.
N1 - Publisher Copyright:
© 2016 Published by Oxford University Press on behalf of ERA-EDTA 2016.
PY - 2016/8/1
Y1 - 2016/8/1
N2 - BackgroundThe protein-bound solutes p-cresol sulfate (PCS) and indoxyl sulfate (IS) accumulate to high plasma levels in renal failure and have been associated with adverse events. The clearance of these bound solutes can be altered independently of the urea clearance by changing the dialysate flow and dialyzer size. This study tested whether a sustained difference in clearance would change the plasma levels of PCS and IS. MethodsFourteen patients on thrice-weekly nocturnal hemodialysis completed a crossover study of two periods designed to achieve widely different bound solute clearances. We compared the changes in pre-dialysis plasma PCS and IS levels from baseline over the course of the two periods. ResultsThe high-clearance period provided much higher PCS and IS clearances than the low-clearance period (PCS: 23 ± 4 mL/min versus 12 ± 3 mL/min, P < 0.001; IS: 30 ± 5 mL/min versus 17 ± 4 mL/min, P < 0.001). Despite the large difference in clearance, the high-clearance period did not have a different effect on PCS levels than the low-clearance period [from baseline, high: +11% (-5, +37) versus low: -8% (-18, +32), (median, 25th, 75th percentile), P = 0.50]. In contrast, the high-clearance period significantly lowered IS levels compared with the low-clearance period [from baseline, high: -4% (-17, +1) versus low: +22% (+14, +31), P < 0.001). The amount of PCS removed in the dialysate was significantly greater at the end of the high-clearance period [269 (206, 312) versus 199 (111, 232) mg per treatment, P < 0.001], while the amount of IS removed was not different [140 (87, 196) versus 116 (89, 170) mg per treatment, P = 0.15]. ConclusionsThese findings suggest that an increase in PCS generation prevents plasma levels from falling when the dialytic clearance is increased. Suppression of solute generation may be required to reduce plasma PCS levels in dialysis patients.
AB - BackgroundThe protein-bound solutes p-cresol sulfate (PCS) and indoxyl sulfate (IS) accumulate to high plasma levels in renal failure and have been associated with adverse events. The clearance of these bound solutes can be altered independently of the urea clearance by changing the dialysate flow and dialyzer size. This study tested whether a sustained difference in clearance would change the plasma levels of PCS and IS. MethodsFourteen patients on thrice-weekly nocturnal hemodialysis completed a crossover study of two periods designed to achieve widely different bound solute clearances. We compared the changes in pre-dialysis plasma PCS and IS levels from baseline over the course of the two periods. ResultsThe high-clearance period provided much higher PCS and IS clearances than the low-clearance period (PCS: 23 ± 4 mL/min versus 12 ± 3 mL/min, P < 0.001; IS: 30 ± 5 mL/min versus 17 ± 4 mL/min, P < 0.001). Despite the large difference in clearance, the high-clearance period did not have a different effect on PCS levels than the low-clearance period [from baseline, high: +11% (-5, +37) versus low: -8% (-18, +32), (median, 25th, 75th percentile), P = 0.50]. In contrast, the high-clearance period significantly lowered IS levels compared with the low-clearance period [from baseline, high: -4% (-17, +1) versus low: +22% (+14, +31), P < 0.001). The amount of PCS removed in the dialysate was significantly greater at the end of the high-clearance period [269 (206, 312) versus 199 (111, 232) mg per treatment, P < 0.001], while the amount of IS removed was not different [140 (87, 196) versus 116 (89, 170) mg per treatment, P = 0.15]. ConclusionsThese findings suggest that an increase in PCS generation prevents plasma levels from falling when the dialytic clearance is increased. Suppression of solute generation may be required to reduce plasma PCS levels in dialysis patients.
KW - Clearance
KW - P-cresol sulfate
KW - Uremia
UR - http://www.scopus.com/inward/record.url?scp=84982162400&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84982162400&partnerID=8YFLogxK
U2 - 10.1093/ndt/gfw100
DO - 10.1093/ndt/gfw100
M3 - Article
C2 - 27190347
AN - SCOPUS:84982162400
SN - 0931-0509
VL - 31
SP - 1335
EP - 1341
JO - Nephrology Dialysis Transplantation
JF - Nephrology Dialysis Transplantation
IS - 8
ER -