Skip to main navigation Skip to search Skip to main content

Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment

Michael W. Smith, D. Murphy, A. Laxmisan, D. Sittig, B. Reis, A. Esquivel, H. Singh

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve followup. Objectives: The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods: We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results: Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. Conclusion: To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.

Original languageEnglish (US)
Pages (from-to)359-375
Number of pages17
JournalApplied Clinical Informatics
Volume4
Issue number3
DOIs
StatePublished - 2013

Keywords

  • Care delays
  • Diagnostic errors
  • Health information technology
  • Patient safety
  • Test results

ASJC Scopus subject areas

  • Health Informatics
  • Computer Science Applications
  • Health Information Management

Fingerprint

Dive into the research topics of 'Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment'. Together they form a unique fingerprint.

Cite this