T1 - Design considerations in the use of interdigitated microsensor electrode arrays (IMEs) for impedimetric characterization of biomimetic hydrogels
AU - Yang, Liju
AU - Guiseppi-Wilson, Adilah
AU - Guiseppi-Elie, Anthony
N1 - Funding Information:
Acknowledgements L. Yang acknowledges support from NC BIO-IMPACT initiative and the Gold Leaf foundation. A Guiseppi-Wilson acknowledges the support of ABTECH Scientific, Inc. and A. Guiseppi-Elie acknowledges support from the US Department of Defense (DoDPRMRP) grant PR023081/DAMD17-03-1-0172 and the Consortium of the Clemson University Center for Bioelectronics, Biosensors and Biochips (C3B).
Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2011/4
Y1 - 2011/4
N2 - Microlithographically fabricated interdigitated microsensor electrodes (IMEs) were cleaned, surface activated, chemically functionalized (amine) and derivatized with an Acrloyl-PEG-NHS to receive a spun-applied monomer cocktail of UV polymerizable monomer. IMEs were 2050.5, 1550.5, 1050.5 and 0550.5 possessing lines and spaces that were 20, 15, 10, and 5 μm respectively; 5 mm line lengths and were 50 lines on each opposing bus. Bioactive hydrogels were synthesized from spun-applied and UV-crosslinked tetraethyleneglycol diacrylate (TEGDA) (crosslinker), 2-hydroxyethylmethacrylate (HEMA), polyethyleneglycol (200) monomethacrylate (PEGMA), N-[tris(hydroxymethyl) methyl]-acrylamide (HMMA) and poly(HEMA) (MW 60,000) (viscosity modifier) and 2,2-dimethoxy-2- phenylacetophenone (DMPA) (photoinitiator) to produce a 5 μm thick p(HEMA-co-PEGMA-co-HMMA) hydrogel membrane on the IMEs. Unmodified and hydrogel coated IMEs where characterized by AC electrical impedance spectroscopy using 50 mV p-t-p over the frequency range from 10 Hz to 100 kHz in aqueous PBS 7.4 buffer and in buffer containing 50 mM [Fe(CN)6]3-/4- solution at RT. Impedimetric responses were found to scale with the device geometric parameters. Equivalent circuit modeling revealed deviations from ideality at lower device dimensions suggesting an implication of the substrate surface charge on the double layer capacitance of the electrodes. Diffusion coefficients derived from the Warburg component are in accord with literature values.
AB - Microlithographically fabricated interdigitated microsensor electrodes (IMEs) were cleaned, surface activated, chemically functionalized (amine) and derivatized with an Acrloyl-PEG-NHS to receive a spun-applied monomer cocktail of UV polymerizable monomer. IMEs were 2050.5, 1550.5, 1050.5 and 0550.5 possessing lines and spaces that were 20, 15, 10, and 5 μm respectively; 5 mm line lengths and were 50 lines on each opposing bus. Bioactive hydrogels were synthesized from spun-applied and UV-crosslinked tetraethyleneglycol diacrylate (TEGDA) (crosslinker), 2-hydroxyethylmethacrylate (HEMA), polyethyleneglycol (200) monomethacrylate (PEGMA), N-[tris(hydroxymethyl) methyl]-acrylamide (HMMA) and poly(HEMA) (MW 60,000) (viscosity modifier) and 2,2-dimethoxy-2- phenylacetophenone (DMPA) (photoinitiator) to produce a 5 μm thick p(HEMA-co-PEGMA-co-HMMA) hydrogel membrane on the IMEs. Unmodified and hydrogel coated IMEs where characterized by AC electrical impedance spectroscopy using 50 mV p-t-p over the frequency range from 10 Hz to 100 kHz in aqueous PBS 7.4 buffer and in buffer containing 50 mM [Fe(CN)6]3-/4- solution at RT. Impedimetric responses were found to scale with the device geometric parameters. Equivalent circuit modeling revealed deviations from ideality at lower device dimensions suggesting an implication of the substrate surface charge on the double layer capacitance of the electrodes. Diffusion coefficients derived from the Warburg component are in accord with literature values.
KW - Arrays
KW - Biosensors
KW - Hydrogels
KW - IME
KW - Impedance
KW - Microfabrication
UR - http://www.scopus.com/inward/record.url?scp=79958119921&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79958119921&partnerID=8YFLogxK
U2 - 10.1007/s10544-010-9492-4
DO - 10.1007/s10544-010-9492-4
M3 - Article
C2 - 21104321
AN - SCOPUS:79958119921
SN - 1387-2176
VL - 13
SP - 279
EP - 289
JO - Biomedical Microdevices
JF - Biomedical Microdevices
IS - 2
ER -