TY - JOUR
T1 - Color Tissue Doppler Myocardial Velocities Consistently Underestimate Spectral Tissue Doppler Velocities
T2 - Impact on Calculation Peak Transmitral Pulsed Doppler Velocity/Early Diastolic Tissue Doppler Velocity (E/Ea)
AU - McCulloch, Marti
AU - Zoghbi, William A.
AU - Davis, Robert
AU - Thomas, Chris
AU - Dokainish, Hisham
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2006/6
Y1 - 2006/6
N2 - Background: Color tissue Doppler (TD) measures mean myocardial velocities, whereas spectral TD measures peak velocities. Given that most data on left ventricular (LV) diastolic function used spectral TD, we investigated whether the differences in myocardial velocities between these modalities resulted in discrepancies in calculated E/Ea. Methods: Patients were imaged using an ultrasound machine. The systolic (Sa), early diastolic (Ea), and late diastolic (Aa) myocardial velocities by color and spectral TD were measured at basal and midsegments of the LV septal, lateral, inferior, and anterior walls in the apical views. The average of basal septal and lateral Ea was combined with the early transmitral diastolic velocity (E) to obtain E/Ea. Results: In all, 31 patients were imaged, with a mean LV ejection fraction of 47.7% ± 19.9. There were significant correlations between Sa, Ea, and Aa by color and spectral TD at all sites (R = 0.92, P < .001 for Ea at basal lateral wall) and between spectral and color E/Ea (R = 0.85, P < .001). Sa, Ea, and Aa were significantly lower by color TD than by spectral TD (basal septal color Ea = 3.0 ± 2.0 cm/s vs 5.6 ± 2.5 cm/s for spectral Ea, P < .001). Consequently, E/Ea by color TD was significantly higher than by spectral TD (22.3 ± 15.3 vs 13.6 ± 7.8, P < .001). Conclusions: Although significant correlations exist, myocardial velocities measured using color TD significantly underestimate velocities by spectral TD. Consequently, E/Ea by color TD significantly overestimates E/Ea using spectral TD, which could lead to errors in assessment of LV diastolic function.
AB - Background: Color tissue Doppler (TD) measures mean myocardial velocities, whereas spectral TD measures peak velocities. Given that most data on left ventricular (LV) diastolic function used spectral TD, we investigated whether the differences in myocardial velocities between these modalities resulted in discrepancies in calculated E/Ea. Methods: Patients were imaged using an ultrasound machine. The systolic (Sa), early diastolic (Ea), and late diastolic (Aa) myocardial velocities by color and spectral TD were measured at basal and midsegments of the LV septal, lateral, inferior, and anterior walls in the apical views. The average of basal septal and lateral Ea was combined with the early transmitral diastolic velocity (E) to obtain E/Ea. Results: In all, 31 patients were imaged, with a mean LV ejection fraction of 47.7% ± 19.9. There were significant correlations between Sa, Ea, and Aa by color and spectral TD at all sites (R = 0.92, P < .001 for Ea at basal lateral wall) and between spectral and color E/Ea (R = 0.85, P < .001). Sa, Ea, and Aa were significantly lower by color TD than by spectral TD (basal septal color Ea = 3.0 ± 2.0 cm/s vs 5.6 ± 2.5 cm/s for spectral Ea, P < .001). Consequently, E/Ea by color TD was significantly higher than by spectral TD (22.3 ± 15.3 vs 13.6 ± 7.8, P < .001). Conclusions: Although significant correlations exist, myocardial velocities measured using color TD significantly underestimate velocities by spectral TD. Consequently, E/Ea by color TD significantly overestimates E/Ea using spectral TD, which could lead to errors in assessment of LV diastolic function.
UR - http://www.scopus.com/inward/record.url?scp=33744508375&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33744508375&partnerID=8YFLogxK
U2 - 10.1016/j.echo.2006.01.020
DO - 10.1016/j.echo.2006.01.020
M3 - Article
C2 - 16762751
AN - SCOPUS:33744508375
SN - 0894-7317
VL - 19
SP - 744
EP - 748
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 6
ER -