TY - JOUR
T1 - Cardiac positron emission tomography and other modalities for coronary artery disease assessment
T2 - A snapshot from the medicare data
AU - Al-Mallah, Mouaz
AU - Alwan, Maria
AU - Al Rifai, Mahmoud
AU - Sayed, Ahmed
N1 - Publisher Copyright:
© 2024 American Society of Nuclear Cardiology
PY - 2024/11
Y1 - 2024/11
N2 - Background: Positron emission tomography (PET) is an important tool for assessing coronary artery disease (CAD), but its widespread utilization is limited due to various factors, including limited local champion availability. This study aims to compare the frequency of PET procedures and their interpreters with other common CAD assessment modalities. Methods: Using Medicare data, we examined the number of cardiac PET procedures billed and compared them with single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA), stress magnetic resonance imaging (MRI), and stress echocardiography. Healthcare Common Procedure Coding System codes were used to identify procedures. We calculated the total number of PET myocardial perfusion imaging (MPI) procedures, the proportion of PET/CT and myocardial blood flow (MBF) assessments, and the median number of studies read per physician. We also analyzed the trends in the use of different CAD assessment modalities between 2018 and 2022. Descriptive statistics summarized the data. Results: In 2022, Medicare billed for 212,106 PET MPI scans. SPECT was six times more frequent (1,343,519), whereas stress echocardiography (201,676) and CCTA (118,734) had similar or lower use. Stress MRI (3,932) was least used. Of the PET MPI scans, 46% were PET/CT, and 39% included MBF measurements. Cardiologists interpreted 86% of PET scans, with a median of 58 studies per reader; 23% interpreted ≤25 studies annually. SPECT had a median of 63 studies per reader, and CCTA, stress MRI, and stress echocardiography had medians of 27, 20, and 24, respectively. PET, CT, and MRI use increased from 2018 to 2022, whereas SPECT and stress echocardiography declined. Conclusion: In the Medicare population, radionuclide perfusion imaging (SPECT and PET) remained the preferred method for assessment of CAD, with SPECT being the most frequently used modality and PET being the second most frequently used modality for this application. However, PET/CT and MBF are underutilized, limiting diagnostic and prognostic capabilities. Efforts to enhance education and awareness of PET's advantages and to address barriers to its wider adoption are essential to maximize its clinical benefits and improve patient outcomes.
AB - Background: Positron emission tomography (PET) is an important tool for assessing coronary artery disease (CAD), but its widespread utilization is limited due to various factors, including limited local champion availability. This study aims to compare the frequency of PET procedures and their interpreters with other common CAD assessment modalities. Methods: Using Medicare data, we examined the number of cardiac PET procedures billed and compared them with single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA), stress magnetic resonance imaging (MRI), and stress echocardiography. Healthcare Common Procedure Coding System codes were used to identify procedures. We calculated the total number of PET myocardial perfusion imaging (MPI) procedures, the proportion of PET/CT and myocardial blood flow (MBF) assessments, and the median number of studies read per physician. We also analyzed the trends in the use of different CAD assessment modalities between 2018 and 2022. Descriptive statistics summarized the data. Results: In 2022, Medicare billed for 212,106 PET MPI scans. SPECT was six times more frequent (1,343,519), whereas stress echocardiography (201,676) and CCTA (118,734) had similar or lower use. Stress MRI (3,932) was least used. Of the PET MPI scans, 46% were PET/CT, and 39% included MBF measurements. Cardiologists interpreted 86% of PET scans, with a median of 58 studies per reader; 23% interpreted ≤25 studies annually. SPECT had a median of 63 studies per reader, and CCTA, stress MRI, and stress echocardiography had medians of 27, 20, and 24, respectively. PET, CT, and MRI use increased from 2018 to 2022, whereas SPECT and stress echocardiography declined. Conclusion: In the Medicare population, radionuclide perfusion imaging (SPECT and PET) remained the preferred method for assessment of CAD, with SPECT being the most frequently used modality and PET being the second most frequently used modality for this application. However, PET/CT and MBF are underutilized, limiting diagnostic and prognostic capabilities. Efforts to enhance education and awareness of PET's advantages and to address barriers to its wider adoption are essential to maximize its clinical benefits and improve patient outcomes.
KW - Myocardial Blood Flow
KW - PET/CT
KW - Positron Emission Tomography
KW - Single Photon Emission Computed Tomography
UR - http://www.scopus.com/inward/record.url?scp=85203786757&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85203786757&partnerID=8YFLogxK
U2 - 10.1016/j.nuclcard.2024.102030
DO - 10.1016/j.nuclcard.2024.102030
M3 - Article
C2 - 39233112
AN - SCOPUS:85203786757
SN - 1071-3581
VL - 41
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
M1 - 102030
ER -