Calculation of electron dose to target cells in a complex environment by Monte Carlo code "CELLDOSE"

Elif Hindié, Christophe Champion, Paolo Zanotti-Fregonara, Domenico Rubello, Nicole Colas-Linhart, Laura Ravasi, Jean Luc Moretti

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Background: We used the Monte Carlo code "CELLDOSE" to assess the dose received by specific target cells from electron emissions in a complex environment. 131I in a simulated thyroid was used as a model. Methods: Thyroid follicles were represented by 170 μm diameter spherical units made of a lumen of 150 μm diameter containing colloidal matter and a peripheral layer of 10 μm thick thyroid cells. Neighbouring follicles are 4 μm apart. 131I was assumed to be homogeneously distributed in the lumen and absent in cells. We firstly assessed electron dose distribution in a single follicle. Then, we expanded the simulation by progressively adding neighbouring layers of follicles, so to reassess the electron dose to this single follicle implemented with the contribution of the added layers. Results: Electron dose gradient around a point source showed that the 131I electron dose is close to zero after 2,100 μm. Therefore, we studied all contributions to the central follicle deriving from follicles within 12 orders of neighbourhood (15,624 follicles surrounding the central follicle). The dose to colloid of the single follicle was twice as high as the dose to thyroid cells. Even when all neighbours were taken into account, the dose in the central follicle remained heterogeneous. For a 1-Gy average dose to tissue, the dose to colloidal matter was 1.168 Gy, the dose to thyroid cells was 0.982 Gy, and the dose to the inter-follicular tissue was 0.895 Gy. Analysis of the different contributions to thyroid cell dose showed that 17.3% of the dose derived from the colloidal matter of their own follicle, while the remaining 82.7% was delivered by the surrounding follicles. On the basis of these data, it is shown that when different follicles contain different concentrations of 131I, the impact in terms of cell dose heterogeneity can be important. Conclusion: By means of 131I in the thyroid as a theoretical model, we showed how a Monte Carlo code can be used to map electron dose deposit and build up the dose to target cells in a complex multi-source environment. This approach can be of considerable interest for comparing different radiopharmaceuticals as therapy agents in oncology.

Original languageEnglish (US)
Pages (from-to)130-136
Number of pages7
JournalEuropean Journal of Nuclear Medicine and Molecular Imaging
Volume36
Issue number1
DOIs
StatePublished - Jan 2009

Keywords

  • Cell dosimetry
  • Iodine-131
  • Monte Carlo simulation
  • Thyroid

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Calculation of electron dose to target cells in a complex environment by Monte Carlo code "CELLDOSE"'. Together they form a unique fingerprint.

Cite this