T1 - Assessment of myocardial blood flow and coronary flow reserve with positron emission tomography in ischemic heart disease
T2 - current state and future directions
AU - Al Badarin, Firas
AU - Aljizeeri, Ahmed
AU - Almasoudi, Fatimah
AU - Al-Mallah, Mouaz H.
N1 - Publisher Copyright:
© 2017, Springer Science+Business Media New York.
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2017/7/1
Y1 - 2017/7/1
N2 - Positron emission tomography (PET) is a versatile imaging technology that allows assessment of myocardial perfusion, both at a spatially relative scale and also in absolute terms, thereby enabling noninvasive evaluation of myocardial blood flow (MBF) and coronary flow reserve (CFR). Assessment of MBF using FDA-approved PET isotopes, such as 82Rb and 13N-ammonia, has been well validated, and several software packages are currently available, thereby allowing for MBF evaluation to be incorporated into routine workflow in contemporary nuclear laboratories. Incremental diagnostic and prognostic information provided with the knowledge of MBF has the potential for widespread applications. Improving the ability to identify the true burden of obstructive epicardial coronary stenoses and allowing for noninvasive assessment of coronary micro circulatory function can be achieved with MBF assessment. On the other hand, attenuated CFR has been shown to predict adverse cardiovascular prognosis in a variety of clinical settings and patient subgroups. With expanding applications of MBF, this tool promises to provide unique insight into the integrity of the entire coronary vascular bed beyond what is currently available with relative perfusion assessment. This review intends to provide an in-depth discussion of technical and clinical aspects of MBF assessment with PET as it relates to patients with ischemic heart disease.
AB - Positron emission tomography (PET) is a versatile imaging technology that allows assessment of myocardial perfusion, both at a spatially relative scale and also in absolute terms, thereby enabling noninvasive evaluation of myocardial blood flow (MBF) and coronary flow reserve (CFR). Assessment of MBF using FDA-approved PET isotopes, such as 82Rb and 13N-ammonia, has been well validated, and several software packages are currently available, thereby allowing for MBF evaluation to be incorporated into routine workflow in contemporary nuclear laboratories. Incremental diagnostic and prognostic information provided with the knowledge of MBF has the potential for widespread applications. Improving the ability to identify the true burden of obstructive epicardial coronary stenoses and allowing for noninvasive assessment of coronary micro circulatory function can be achieved with MBF assessment. On the other hand, attenuated CFR has been shown to predict adverse cardiovascular prognosis in a variety of clinical settings and patient subgroups. With expanding applications of MBF, this tool promises to provide unique insight into the integrity of the entire coronary vascular bed beyond what is currently available with relative perfusion assessment. This review intends to provide an in-depth discussion of technical and clinical aspects of MBF assessment with PET as it relates to patients with ischemic heart disease.
KW - Coronary artery disease
KW - Coronary flow reserve
KW - Myocardial blood flow
KW - Positron emission tomography
UR - http://www.scopus.com/inward/record.url?scp=85020277682&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85020277682&partnerID=8YFLogxK
U2 - 10.1007/s10741-017-9625-4
DO - 10.1007/s10741-017-9625-4
M3 - Review article
C2 - 28593557
AN - SCOPUS:85020277682
SN - 1382-4147
VL - 22
SP - 441
EP - 453
JO - Heart Failure Reviews
JF - Heart Failure Reviews
IS - 4
ER -