T1 - An image processing algorithm for the in-vivo quantification and visualization of septum motion in type III B
AU - Karmonik, Christof
AU - Bismuth, Jean
AU - Davies, Mark G.
AU - Younes, Houssam K.
AU - Lumsden, Alan B.
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2009/12/1
Y1 - 2009/12/1
N2 - Currently, there is no method to predict outcome of endovascular treatment (EVAR) of type III B aortic dissections (TB-AD). A new image processing algorithm is presented for quantifying IS displacement from cine 2D phase contrast magnetic resonance images (2D pcMRI) towards a new classification of TB-AD based on IS mobility, Bulk motion of the true aortic lumen (tAB) center (ALC), maximum, minimum and average displacement of the boundary points composing the IS and tAB excluding the IS were quantified at two locations in one patient. Correlations of the ALC motion and the averaged temporal displacement AD(t) of IS and tAB excluding IS with the aortic flow waveform were calculated. Range of ALC motion was similar in both locations ( average 0.56 mm, max 1.37 mm) and correlated with the aortic flow waveform in the abdominal aorta but not the thoracic aorta. Range of displacement of the IS was from 1.27 mm to -1.64 mm (average 0.09 ± 0.07 mm) in the thoracic aorta, and from 0.38 mm to -3.38 mm (average 0.42 ± 0.23 mm) in the abdominal aorta. tAB motion excluding the IS was 1.21 mm to 0.84 mm (thoracic, average 0.13 ± 0.07 mm) and 0.52mm to -1.88 mm (abdominal, average 0.37 ± 0.11 mm). AD(t) for IS and tAB excluding the IS both correlated with aortic flow in the abdominal aorta only.
AB - Currently, there is no method to predict outcome of endovascular treatment (EVAR) of type III B aortic dissections (TB-AD). A new image processing algorithm is presented for quantifying IS displacement from cine 2D phase contrast magnetic resonance images (2D pcMRI) towards a new classification of TB-AD based on IS mobility, Bulk motion of the true aortic lumen (tAB) center (ALC), maximum, minimum and average displacement of the boundary points composing the IS and tAB excluding the IS were quantified at two locations in one patient. Correlations of the ALC motion and the averaged temporal displacement AD(t) of IS and tAB excluding IS with the aortic flow waveform were calculated. Range of ALC motion was similar in both locations ( average 0.56 mm, max 1.37 mm) and correlated with the aortic flow waveform in the abdominal aorta but not the thoracic aorta. Range of displacement of the IS was from 1.27 mm to -1.64 mm (average 0.09 ± 0.07 mm) in the thoracic aorta, and from 0.38 mm to -3.38 mm (average 0.42 ± 0.23 mm) in the abdominal aorta. tAB motion excluding the IS was 1.21 mm to 0.84 mm (thoracic, average 0.13 ± 0.07 mm) and 0.52mm to -1.88 mm (abdominal, average 0.37 ± 0.11 mm). AD(t) for IS and tAB excluding the IS both correlated with aortic flow in the abdominal aorta only.
UR - http://www.scopus.com/inward/record.url?scp=77950978390&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950978390&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2009.5333811
DO - 10.1109/IEMBS.2009.5333811
M3 - Conference contribution
C2 - 19964359
AN - SCOPUS:77950978390
SN - 9781424432967
T3 - Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
SP - 4391
EP - 4394
BT - Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 2 September 2009 through 6 September 2009
ER -