TY - JOUR
T1 - Albumin-impregnated prosthetic graft for infrarenal aortic replacement
T2 - Effects on the incidence and volume of perioperative blood transfusion
AU - Chakfé, Nabil
AU - Beaufigeau, Marc
AU - Nicolini, Philippe
AU - Epailly, Eric
AU - Levy, François
AU - Thiranos, Jean Claude
AU - Petit, Hélène
AU - Kieny, René
AU - Kretz, Jean Georges
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1997/11
Y1 - 1997/11
N2 - We retrospectively reviewed 290 cases in which an albumin-impregnated polyester prosthetic graft was used for surgical management of aortic bifurcation disease between November 1987 and December 1990. The purpose of this review was to determine the incidence and volume of blood transfusion and to evaluate the rate of patency and the incidence of infection achieved using this type of prosthesis. The indication for surgery was abdominal aortic aneurysm (AAA) in 218 cases (190 elective procedures and 28 emergency procedures) and occlusive disease of the aortic bifurcation (ODAB) in 72 cases. Mean follow-up was 25.5 ± 13.4 months (range: 1 and 50 months). The incidence of blood transfusion for elective AAA and ODAB surgery was 30.2% and 32.3% intraoperatively, 21.3% and 12.9% postoperatively, and 40.4% and 42.6% overall. The mean number of red cell packs transfused for elective AAA and ODAB surgery was respectively 1 and 0.8 intraoperatively, 0.4 and 0.6 postoperatively, and 1.4 and 1 overall. No immediate or late graft infection prosthesis was observed in any patient in this series. Primary and secondary patency was 95.5% and 97.5% at 6 months with no graft thrombosis during further follow-up. The fact that use of an impregnated graft in management of aortic bifurcation disease was accompanied by a high incidence and volume of blood transfusion suggests that these grafts do not reduce perioperative blood loss. Use of an impregnated prosthesis had no effect on the rate of patency and the incidence infection.
AB - We retrospectively reviewed 290 cases in which an albumin-impregnated polyester prosthetic graft was used for surgical management of aortic bifurcation disease between November 1987 and December 1990. The purpose of this review was to determine the incidence and volume of blood transfusion and to evaluate the rate of patency and the incidence of infection achieved using this type of prosthesis. The indication for surgery was abdominal aortic aneurysm (AAA) in 218 cases (190 elective procedures and 28 emergency procedures) and occlusive disease of the aortic bifurcation (ODAB) in 72 cases. Mean follow-up was 25.5 ± 13.4 months (range: 1 and 50 months). The incidence of blood transfusion for elective AAA and ODAB surgery was 30.2% and 32.3% intraoperatively, 21.3% and 12.9% postoperatively, and 40.4% and 42.6% overall. The mean number of red cell packs transfused for elective AAA and ODAB surgery was respectively 1 and 0.8 intraoperatively, 0.4 and 0.6 postoperatively, and 1.4 and 1 overall. No immediate or late graft infection prosthesis was observed in any patient in this series. Primary and secondary patency was 95.5% and 97.5% at 6 months with no graft thrombosis during further follow-up. The fact that use of an impregnated graft in management of aortic bifurcation disease was accompanied by a high incidence and volume of blood transfusion suggests that these grafts do not reduce perioperative blood loss. Use of an impregnated prosthesis had no effect on the rate of patency and the incidence infection.
UR - http://www.scopus.com/inward/record.url?scp=0030724206&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030724206&partnerID=8YFLogxK
U2 - 10.1007/s100169900096
DO - 10.1007/s100169900096
M3 - Article
C2 - 9363304
AN - SCOPUS:0030724206
SN - 0890-5096
VL - 11
SP - 588
EP - 595
JO - Annals of Vascular Surgery
JF - Annals of Vascular Surgery
IS - 6
ER -