T1 - Albumin-impregnated polyester vascular prosthesis for abdominal aortic surgery
T2 - An improvement?
AU - Chakfe, N.
AU - Kretz, J. G.
AU - Petit, H.
AU - Epailly, E.
AU - Nicolini, P.
AU - Levy, F.
AU - Pasquali, J. L.
AU - Eisenmann, B.
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1996
Y1 - 1996
N2 - Aim: To compare the peroperative blood loss and the postoperative systemic inflammatory reaction in patients receiving either a Vasculour II Albumin pre-impregnated prosthesis (VA group, n = 32) or a preclotted Vasculour II prosthesis (VA group, n = 33) for elective surgery of the abdominal aorta. Setting: University Hospital. Design: Prospective, randomised study. Methods: Peroperative blood loss was measured over two different periods: Phase I from the beginning of the operation to the completion of the proximal anastomosis, when blood loss cannot be related to the model of prosthesis implanted and phase II after the completion of the proximal anastomosis to the end of the operation. Postoperative blood loss was evaluated by the determination of the retroperitoneal drainage volume over a period of 2 days immediately following the operation. The presence of perisprosthetic fluid was measured with echography at days 4, 9, 30 and 60. The postoperative systemic inflammatory reaction was evaluated by measuring the sedimentation rate and the C reactive protein levels daily from day 1 to day 9, and at days 14, 21, 28, 45, and 60, and by measuring the body temperature daily from day 1 to day 9. Results: No significant differences of peroperative blood loss were observed. The same proportion of patients (35%) in both groups received homologous transfusion. The mean number of units of homologous blood transfused per patient was respectively 0.77 and 0.91 for the VA and the V group. The retroperitoneal drainage volume and the percentage of patients with perisprosthetic fluid did not differ significantly. No significant differences in systemic postoperative inflammatory reaction were observed. Conclusion: There were no benefits in using albumin-impregnated prosthesis as opposed to preclotted prosthesis in terms of peroperative and postoperative blood loss, or by looking at the incidence of homologous blood transfusion. However; the glutaraldehyde cross-linked albumin did not induce any systemic inflammatory reaction.
AB - Aim: To compare the peroperative blood loss and the postoperative systemic inflammatory reaction in patients receiving either a Vasculour II Albumin pre-impregnated prosthesis (VA group, n = 32) or a preclotted Vasculour II prosthesis (VA group, n = 33) for elective surgery of the abdominal aorta. Setting: University Hospital. Design: Prospective, randomised study. Methods: Peroperative blood loss was measured over two different periods: Phase I from the beginning of the operation to the completion of the proximal anastomosis, when blood loss cannot be related to the model of prosthesis implanted and phase II after the completion of the proximal anastomosis to the end of the operation. Postoperative blood loss was evaluated by the determination of the retroperitoneal drainage volume over a period of 2 days immediately following the operation. The presence of perisprosthetic fluid was measured with echography at days 4, 9, 30 and 60. The postoperative systemic inflammatory reaction was evaluated by measuring the sedimentation rate and the C reactive protein levels daily from day 1 to day 9, and at days 14, 21, 28, 45, and 60, and by measuring the body temperature daily from day 1 to day 9. Results: No significant differences of peroperative blood loss were observed. The same proportion of patients (35%) in both groups received homologous transfusion. The mean number of units of homologous blood transfused per patient was respectively 0.77 and 0.91 for the VA and the V group. The retroperitoneal drainage volume and the percentage of patients with perisprosthetic fluid did not differ significantly. No significant differences in systemic postoperative inflammatory reaction were observed. Conclusion: There were no benefits in using albumin-impregnated prosthesis as opposed to preclotted prosthesis in terms of peroperative and postoperative blood loss, or by looking at the incidence of homologous blood transfusion. However; the glutaraldehyde cross-linked albumin did not induce any systemic inflammatory reaction.
KW - Abdominal aortic surgery
KW - Albumin-impregnated
KW - Blood loss
KW - Blood vessel prosthesis
KW - Inflammatory reaction
KW - Polyester
KW - Randomised controlled trial
UR - http://www.scopus.com/inward/record.url?scp=0029974151&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029974151&partnerID=8YFLogxK
U2 - 10.1016/S1078-5884(96)80255-3
DO - 10.1016/S1078-5884(96)80255-3
M3 - Article
C2 - 8896479
AN - SCOPUS:0029974151
VL - 12
SP - 346
EP - 353
JO - European Journal of Vascular and Endovascular Surgery
JF - European Journal of Vascular and Endovascular Surgery
SN - 1078-5884
IS - 3
ER -