TY - JOUR
T1 - A quick assay for monitoring recombinant hirudin during cardiopulmonary bypass in patients with heparin-induced thrombocytopenia type II
T2 - Adaptation of the ecarin clotting time to the ACT II device
AU - Koster, Reas
AU - Loebe, Matthias
AU - Hansen, Roland
AU - Bauer, Mathias
AU - Mertzlufft, Fritz
AU - Kuppe, Hermann
AU - Hetzer, Roland
N1 - Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2000
Y1 - 2000
N2 - Background: Recombinant hirudin is increasingly advocated as a promising alternative anticoagulation for patients with heparin-induced thrombocytopenia type II during cardiopulmonary bypass. This requires monitoring of the ecarin clotting time. No commercial ecarin clotting time assay is available for clinical use. We adapted the ecarin clotting time to the easy-to-handle ACT II device. Methods: Three different concentrations of the ecarin reagent (20, 10, 5 U/mL) were investigated as preliminary studies. Standard calibration curves were constructed for concentrations of recombinant hirudin ranging from 0 to 5 μg/mL. In vivo samples were collected from patients with heparin-induced thrombocytopenia type II who underwent cardiopulmonary bypass, and the values were compared with the values obtained by the chromogenic method. The final concentration for the assay of 5 IU/mL ecarin was further assessed in vitro for reproducibility and the influence of variations in hematocrit, platelet count, and procoagulants. Results: All three concentrations of ecarin revealed linearity to 5 μg/mL concentrations of recombinant hirudin. The ecarin concentration of 5 U/mL revealed the best correlation (0.87) to the laboratory method, was reproducible over the whole recombinant hirudin range, and was not influenced by the variations in the in vitro setup. Conclusions: The ACT II/ecarin clotting time with an ecarin concentration of 5 U/mL is a simple and reliable assay for monitoring recombinant hirudin during cardiopulmonary bypass. Use of this assay allows a wider use of recombinant hirudin in patients with heparin-induced thrombocytopenia type II during bypass and thereby may contribute to the safer management of these patients.
AB - Background: Recombinant hirudin is increasingly advocated as a promising alternative anticoagulation for patients with heparin-induced thrombocytopenia type II during cardiopulmonary bypass. This requires monitoring of the ecarin clotting time. No commercial ecarin clotting time assay is available for clinical use. We adapted the ecarin clotting time to the easy-to-handle ACT II device. Methods: Three different concentrations of the ecarin reagent (20, 10, 5 U/mL) were investigated as preliminary studies. Standard calibration curves were constructed for concentrations of recombinant hirudin ranging from 0 to 5 μg/mL. In vivo samples were collected from patients with heparin-induced thrombocytopenia type II who underwent cardiopulmonary bypass, and the values were compared with the values obtained by the chromogenic method. The final concentration for the assay of 5 IU/mL ecarin was further assessed in vitro for reproducibility and the influence of variations in hematocrit, platelet count, and procoagulants. Results: All three concentrations of ecarin revealed linearity to 5 μg/mL concentrations of recombinant hirudin. The ecarin concentration of 5 U/mL revealed the best correlation (0.87) to the laboratory method, was reproducible over the whole recombinant hirudin range, and was not influenced by the variations in the in vitro setup. Conclusions: The ACT II/ecarin clotting time with an ecarin concentration of 5 U/mL is a simple and reliable assay for monitoring recombinant hirudin during cardiopulmonary bypass. Use of this assay allows a wider use of recombinant hirudin in patients with heparin-induced thrombocytopenia type II during bypass and thereby may contribute to the safer management of these patients.
UR - http://www.scopus.com/inward/record.url?scp=0034043175&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034043175&partnerID=8YFLogxK
U2 - 10.1067/mtc.2000.106088
DO - 10.1067/mtc.2000.106088
M3 - Article
C2 - 10838548
AN - SCOPUS:0034043175
SN - 0022-5223
VL - 119
SP - 1278
EP - 1283
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
IS - 6
ER -